8. Electric characteristics
39
THERMA V Split Type
Outdoor unit
DHW Tank integrated Unit
Model
Power Supply
for Electric Heater
Indoor Unit
Combination of
Electric Heater
(kW)
Phase
Volts
Hz
Capacity (kW) Power
Circuit Breaker
(A)
AHNW16606B0
2.0
1~
220-240V
50Hz
2.0 1~ 230V 50Hz 16.0
2.0+2.0
1~
220-240V
50Hz
4.0 1~ 230V 50Hz 20.0
2.0+2.0+2.0
3N~
380-415V
50Hz
6.0 3N~ 400V 50Hz 16.0
[Power Supply for Heat Pump]
[Power Supply for Electric Heater]
Note
1.Voltage supplied to the unit terminals should be within the minimum and maximum range.
2.Maximum allowable voltage unbalance between phase is 2%.
3.Recommended circuit breaker type is ELCB (Earth Leakage Circuit Breaker).
Main
for Heat Pump
Power source
Switch box
ELCB
Outdoor
Indoor
for Indoor Unit
Power source
Switch box
ELCB
Main
Communication line
Main
for Heat Pump
Power source
Switch box
ELCB
Switch box
ELCB
Outdoor
Indoor
for Heater
Power source
for Indoor Unit
Power source
Switch box
ELCB
Main
Communication line