9. Installation
19
THERMA V Split Type
Hydro Box Unit
CASE2 : Connecting DHW tank
(Under floor loop, Fan coil unit and Radiator)
CASE3 : Connecting Solar thermal system
Outdoor Indoor
Fan coil unit Floor heating loop
Domestic
hot water
tank
Hot water
City water
Radiator
Outdoor
Unit
Indoor
Unit
※ According to each model, external appearance of
outdoor/indoor units could be different.
M/F
Magnetic
Filter
(Recommended)
Room Thermostat(Field supply)
2way valve
(Field supply)
By-pass valve(Field supply)
High Temperature
Low Temperature
Shut-off valve
3way valve
(Field supply)
Pump(Field supply)
Solar heat source
Outdoor Indoor
Fan coil unit Floor heating loop
Domestic
hot water
tank
Hot water
City water
Radiator
Outdoor
Unit
Indoor
Unit
※ According to each model, external appearance of
outdoor/indoor units could be different.
M/F
Magnetic
Filter
(Recommended)