ERROR SYMPTOM CAUSE
8
9
10
MAIN PWB ASSEMBLY is out of order
󳢹 Replace the MAIN PWB ASSEMBLY
Winding in the STATOR ASSEMBLY is short-circuited.
󳢹 Replace the STATOR ASSEMBLY
is dispplayed during a high spin
󳢹 Replace the LEAD WIRE ASSEMBLY (MOTOR)
The connector in the LEAD WIRE ASSEMBLY is not connected to
the connnector of STATOR ASSEMBLY
󳢹 Reconnect or repair the connector
The hall sensor is out of order/defective.
󳢹 Replace the STATOR ASSEMBLY
The Dry Heater is out of order
󳢹 Replace the Dry Heater
The Connector of the Dry Heater is not connected properly to the
connector in the Main PWB ASSEMBLY
󳢹 Reconnect or repair the connector
The Dry fan motor is out of order
󳢹 Replace the fan Motor.
CURRENT
ERROR
MOTOR
ERROR
DRY
HEATOR
ERROR
15