ERROR DECISION CAUSE FOR ERROR
BASIS OCCURRENCE
REMEDYERROR
LID is opened in the
course of intermittent
spin, normal spin or
processing reservation
.
SIGNAL continuously
ringing.
Water Pressure Switch
is off.
AUTO OFF relay S/W
is out of order.
DOOR
OPEN
PRESSURE
SENSOR
AUTO OFF
OVER
FLOODING
ERROR
Lid is opened during
intermittent spin or normal spin?
Lid is opened while processing
reservation?
Connector to the S.F S/W or
VIOLET(VL) 2 PIN CONNECTOR
to the P.W.B ASM has bad
connection.
S.F S/W is bad or bad contact.
Connector the PRESSURE S/W
ASM or BLUE(BL) 3 pin connector
to P.W.B ASM has bad connection.
PRESSURE S/W is bad.
(In the initial state of QC TEST
MODE, the number on the
DISPLAY is less than 63 or more
than 70)
BLUE(BL) 1pin connector to P.W.B
ASM has bad connection.
Check water leakage or
whether the drain hose is hung
on to drainage which is min 0.9
obove from floor.
Check blockage of air hole or
air tube.
Check & repair air leakage at
the air hole of outer tub the air
tube or connection parts.
Closed the lid.
Closed the lid.
Correct the connector contact.
Check and replace S.F S/W.
or BALL SENSOR.(WF-T851)
Correct the connector contact.
Replace PRESSURE S/W ASM.
Correct the connector contact.
Change P.W.B ASM.
Hang drain hose which is
minimum 0.9m above from floor.
Replace pressure sensor
switch
Remove the foreign objects in
pressure sensor switch
DOOR Er.
lamp blinks
displayed
WF-T851/T853/T652/
T652A/T452/T452A
WF-T802/T852/T902