4-8. TROUBLE SHOOTING M ETHODS ACCORDING TO ERROR M ESSAGE
For more detailed information for trouble shooting refer to page 46 to 57.
ERROR DECISION CAUSE FOR ERROR
BASIS OCCURRENCE
REMEDYERROR
WATER LEVEL
does not rise to the
set level in 40
minutes.
Water is not
completely drained
in 10 minutes.
Laundry unbalance
during spin.
In the second QC
Mode the following
message is displayed.
WATER
SUPPLY
& INLET
V/V.
DRAINAGE
UNBALANCE
OVER
FLOODING
ERROR
Water faucet is closed?
Water supply is interrupted.
Inlet V/V is clogged with dirts.
Connector has bad contact to
the inlet valve.
Yellow(YL) 2 pin connector has
bad contact to the P.W.B ASM.
Is the drain hose located
properly?
Drain hose is not lowered.
Drain hose is folded or clogged
due to freeze or dirts.
Bad Drain Motor part or
WHITE(WH) 2 pin connector to
the P.W.B ASM has bad
connection.
Laundry in the INNER TUB is
filled unevenly.
Washer is tilted.
S.F S/W is too closed to the
washing tub, or has bad contact.
Is the CONNECTOR of Ball
pressure sensor disconnected
or badly tonched?
Check INLET valve
Open water faucet.
Wait until water supply is
resumed.
Clean or replace filter.
Correct the connector contact.
Same as above.
Hung up drain hose at 0.9~1.3m
high. (For pump)
Put the hose lower.
(For : Non-pump)
Unclog the drain hose.
Replace Drain Motor or correct
the connector contact.
Try to fill laundry uniformly in the
inner tub.
Adjust the leg.
Check and replace S.F S/W.
Check B.P SENSOR
CONNECTOR or replace B.P
sensor