ERROR DECISION CAUSE FOR ERROR
BASIS OCCURRENCE
REMEDYERROR
Water Pressure Switch
is off.
AUTO OFF relay S/W
is out of order.
PRESSURE
SENSOR
AUTO OFF
OVER
FLOODING
ERROR
MOTOR
ERROR
Current
Error
Connector the PRESSURE S/W
ASM or RED(ORANGE or PINK) 4
pin connector to P.W.B ASM has
bad connection.
PRESSURE S/W is bad.
(In the initial state of QC TEST MODE,
For WT-R80(5)1
the number on the DISPLAY is less
than 63 or more than 70
Except
for WT-R80(5)1
the number on the DISPLAY is
less than 60 or more than 104)
Check water leakage or
whether the drain hose is hung
on to drainage which is 0.9 m
obove from floor.
Check blockage of air hole or
air tube.
Check & repair air leakage at
the air hole of outer tub the air
tube or connection parts.
Connector the HALL Sensor or
Natural 6 Pin connector to P.W.B
ASM had bad connection .
Connector the stator ASM, and
YELLOW(GREEN) 3 Pin or
Natural 6 Pin connector to P.W.B
ASM had bad connection
Hall sensor is bad.
Locked by Bearing Housing
IPM is bed
Motor is short
Correct the connector contact.
Replace PRESSURE S/W ASM.
Change P.W.B ASM.
Hang drain hose which is
minimum 0.9m above from floor.
Replace pressure sensor
switch
Remove the foreign objects in
pressure sensor switch
Correct the connect contact.
Change Stator ASM.
Change Bearing Housing ASM.
Change P.W.B ASM.
Change Stator ASM.
Change PWB ASM
Change Stator ASM