30
LOCKED MOTOR ERROR
Yes
Is displayed?
Reconnect
the connector
(connector /
wire / motor)
Check the connectors below.
Is the connector disconnected
or disassembled?
(motor hall sensor connector,
motor drive connector)
- Main PCB Assembly
(YL3, BL6)
Motor Drive
Hall Sensor
- part of wire
Yes
No
No
Is rotor magnet cracked?
Is hall sensor out of order ?
Yes
Yes
Replace the MAIN PCB
No
Yes
Is the resistance values
in the range of 5 to15 Ω?
(U-V, V-W, W-V
:U=1, V=2, W=3)
- After pull out the YL3
connector, check the
terminal of the connector in
wire.
No
Replace
the ROTOR
Replace
the STATOR
Replace
the Hall
sensor
- part of motor