Maintenance Manual of Elevating Work Platform
6
1.6 Details of A14JE Maintenance Parts
Rotary support,
first 50h
Hydraulic Oil
return filter(If
equipped)
Gear oil GL-5
85W-90 barrel
For the first-time
operation of the
reducer,
replenish oil after
150h. Later,
replenish oil
every 250h.
Oil suction filter
WU-63x180-J
Maintenance items of every level are given in the following table
Charging with matching
charger
1. No matter whether the battery is loaded or not, if
the battery is not charged for a long time, the
service life of the battery will be shortened.
2. For the battery that has been loaded, in addition
to the above maintenance measures, the power
main switch should be disconnected timely when
the battery is not in use for a long time
Check whether the battery plate is bare. If the plate
is bare, only add water to the discharged or partially
charged battery. In this case, add water just above
the plate, then charge the battery, then add water to
3mm/0.12in below the exhaust well (plastic cover in
the exhaust hole), and reassemble the vent cap
after adding water.
1. Check whether there is burned, worn, corroded,
extruded and loosen wiring
2. Check whether all harness joints except
connectors are coated with sufficient insulating
grease.