Liebert® PDX and PCW™
ThermalManagementSystems
3 to 8 Ton (11 to 29 kW) Capacity,
UpflowandDownflow,60Hz
Installer/User Guide

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Liebert PX029 and is the answer not in the manual?

Liebert PX029 Specifications

General IconGeneral
Frequency50/60 Hz
ModelPX029
Input Voltage200-240 VAC
Output Voltage200-240 VAC
PhaseSingle-phase
OutletsC13
Dimensions (H x W x D)1791mm x 56mm x 51mm
Weight6.4kg

Summary

IMPORTANT SAFETY INSTRUCTIONS

Electrical Hazard Warnings

Warns about arc flash, shock, and safe electrical practices.

Refrigeration System Pressure Hazards

Highlights dangers of high-pressure refrigerant discharge and system safety.

Rotating Fan Impeller Hazards

Warns about fan blade hazards and required safety measures.

EQUIPMENT INSPECTION AND HANDLING

Handling Safety Warnings and Procedures

Lists critical safety warnings and procedures for moving, lifting, and unpacking the equipment.

PIPING AND REFRIGERANT REQUIREMENTS

Gravity-Fed Drain Line Installation Requirements

Details requirements for installing gravity-fed drain lines, including warnings.

Refrigerant Piping and Charging

Refrigerant System Safety Warnings

Warns about over-pressurization and oil contamination risks during refrigerant handling.

Air-Cooled System Refrigerant Piping Guidelines

Provides guidelines for installing refrigerant piping for air-cooled systems.

Refrigerant Line Sizing and Equivalent Lengths

Lists recommended refrigerant line sizes based on equivalent pipe lengths.

Air-Cooled System Refrigerant Charge Requirements

Provides approximate R-410A refrigerant charge for air-cooled PDX units.

Additional Compressor Oil Requirements

Specifies additional oil needed based on system charge levels.

Evacuation, Leak-Testing, and Charging Air-Cooled Systems (TXV/No Receivers)

Details the process for evacuating, leak-testing, and charging air-cooled systems.

Calculating System Refrigerant Charge

Guides on calculating the correct system refrigerant charge.

Target Subcooling Based on Ambient Temperature

Provides target subcooling temperatures based on outdoor ambient conditions.

Evacuation, Leak-testing, and Charging Air-cooled Systems with Liebert Lee-Temp™

Lee-Temp Receiver Evacuation and Leak-Testing

Details evacuation and leak-testing procedures for systems with Liebert Lee-Temp receivers.

Evacuation, Leak-testing and Charging Air-cooled Systems with EEV and Unheated Receivers

Evacuation and Leak-testing Systems with Unheated Receivers

Details evacuation and leak-testing for systems with EEV and unheated receivers.

Charging Air-Cooled Systems with Unheated Receivers

Guides on charging air-cooled systems with unheated receivers.

Superheat and Refrigerant Charge Optimization

Covers superheat optimization for Liebert PDX units.

Optimizing Refrigerant Charge on Water/Glycol Units

Optimizing Water/Glycol Refrigerant Charge

Details steps to optimize refrigerant charge for water/glycol systems.

Water/Glycol and Chilled-water Loop Piping Guidelines

Coolant System Corrosion and Freezing Prevention

Warns about leaks and damage from improper coolant mixtures and freezing.

No-Flow Condition and Leak Checking Procedures

Explains no-flow risks and provides guidance on leak checking piping.

ELECTRICAL CONNECTIONS

Three-Phase Electrical Service Requirements

Details requirements for three-phase electrical service and conformance to codes.

Electrical Connection Safety Hazards

Warns about electrical hazards and necessary precautions during connections.

Power Connection and Grounding Requirements

Covers power connection, grounding, and input power requirements.

CHECKLIST FOR COMPLETED INSTALLATION

Piping Installation Checks

Checklist items for ensuring proper piping completion and leak checks.

INITIAL START-UP CHECKS AND COMMISSIONING PROCEDURE FOR WARRANTY INSPECTION

Start-Up Safety Warnings

Warns about electrical, handling, and smoke hazards during start-up.

Warranty Inspection and Contacting Vertiv

Guides on completing the warranty inspection and contacting Vertiv for support.

MAINTENANCE

Maintenance Safety Warnings

Warns about electrical, handling, and operational hazards during maintenance.

Filter Maintenance and Replacement

Discusses filter maintenance, replacement procedures, and filter specifications.

EC Fan Blower Drive System Maintenance

Covers maintenance for EC fan blower drive systems, including safety and impeller checks.

EC-Fan Alarm Contact Tests and Downflow Fan Replacement

Explains EC fan alarm checks and provides steps for replacing EC fans in downflow models.

Steam-generating Humidifier Maintenance

Warns about risks associated with improper humidifier canister maintenance.

Air-Cooled Condenser and Drycooler Maintenance

Details maintenance for air-cooled condensers and drycoolers to ensure efficiency.

Thermostatic Expansion Valve (TXV) Maintenance

Explains the function and maintenance of the TXV for evaporator refrigerant supply.

Determining Suction Superheat

Outlines the procedure for determining suction superheat.

Adjusting Superheat Setting with the TXV

Details how to adjust the superheat setting using the TXV.

Electronic Expansion Valve (EEV) Maintenance

Covers maintenance for the EEV, including safety warnings and troubleshooting notes.

Compressor Maintenance

Discusses compressor oil types, viscosities, and handling precautions.

Scroll and Digital-scroll Compressor Maintenance

Covers maintenance for scroll and digital-scroll compressors.

Replacing the Compressor

Step-by-step instructions and safety warnings for replacing the compressor.

Facility Fluid and Piping Maintenance for Water and Glycol Systems

Covers maintenance requirements for facility water and glycol piping systems.

PREVENTIVE MAINTENANCE CHECKLIST

Compressor Section Maintenance Checks

Details checks for compressor oil, mounts, wiring, operation, and refrigerant leaks.

LIEBERT MC CONDENSER ELECTRICAL FIELD CONNECTIONS PREMIUM EFFICIENCY CONTROL

LIEBERT PDX PIPING SCHEMATIC AIR COOLED MODELS WITH TXV

LIEBERT PCW PIPING SCHEMATIC CHILLED WATER MODELS

LIEBERT PDX PIPING SCHEMATIC WATER/GLYCOL MODELS

LIEBERT PDX PIPING SCHEMATIC GLYCOOL™ MODELS

LIEBERT PDX & PCW ELECTRICAL FIELD CONNECTIONS UPFLOW & DOWNFLOW MODELS

LIEBERT PDX & PCW ELECTRICAL FIELD CONNECTIONS DOWNFLOW MODELS

LIEBERT PDX & PCW ELECTRICAL FIELD CONNECTIONS UPFLOW MODELS

LIEBERT PDX PRIMARY CONNECTION LOCATIONS DOWNFLOW AIR COOLED MODELS

LIEBERT PDX PRIMARY CONNECTION LOCATIONS UPFLOW AIR COOLED MODELS

LIEBERT PCW PRIMARY CONNECTION LOCATIONS DOWNFLOW CHILLED WATER MODELS

LIEBERT PCW PRIMARY CONNECTION LOCATIONS UPFLOW CHILLED WATER MODELS

LIEBERT PDX PRIMARY CONNECTION LOCATIONS DOWNFLOW WATER/GLYCOL MODELS

LIEBERT PDX PRIMARY CONNECTION LOCATIONS UPFLOW WATER/GLYCOL MODELS

LIEBERT PDX PRIMARY CONNECTION LOCATIONS DOWNFLOW FRONT DISCHARGE AIR COOLED MODELS

LIEBERT PCW PRIMARY CONNECTION LOCATIONS DOWNFLOW FRONT DISCHARGE MODELS

LIEBERT PDX PRIMARY CONNECTION LOCATIONS DOWNFLOW GLYCOOL™ MODELS

LIEBERT PDX OPTIONAL PIPING SCHEMATICS ECON-O-COIL MODELS

LIEBERT PDX CANbus & INTERLOCKCONNECTIONS BETWEEN PDX UNIT & LIEBERT MC CONDENSER (PREMIUM)

LIEBERT PDX PRIMARY CONNECTION LOCATIONS UPFLOW GLYCOOL™ MODELS

LIEBERT PDX PRIMARY CONNECTION LOCATIONS DOWNFLOW FRONT DISCHARGE GLYCOOL™ MODELS

LIEBERT PCW OPTIONAL PIPING SCHEMATIC HOT WATER REHEAT

LIEBERT PDX PIPING SCHEMATIC AIR COOLED MODELS WITH EEV