Liebert® PDX and PCW™
ThermalManagementSystems
3 to 8 Ton (11 to 29 kW) Capacity,
UpflowandDownflow,60Hz
Installer/User Guide

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Liebert PW029 and is the answer not in the manual?

Liebert PW029 Specifications

General IconGeneral
BrandLiebert
ModelPW029
CategoryControl Unit
LanguageEnglish

Summary

1 Important Safety Instructions

Electrical Safety and Arc Flash Hazards

Details electrical hazards and necessary safety precautions.

Refrigeration System Over-Pressurization Risks

Cautions against high pressure in the refrigeration system.

Fan Blade Contact and Handling Hazards

Warns about injury from rotating fan blades and improper handling.

Electrical Connection and Wiring Hazards

Highlights risks from improper wiring and loose electrical connections.

Humidifier Safety and Fire Risks

Addresses fire hazards related to humidifier canister maintenance.

Refrigerant Line Pressure and System Safety

Cautions about refrigerant line pressure and system safety.

4 Equipment Inspection and Handling

4.2 Handling the Unit while Packaged

Provides guidance on using forklifts or pallet jacks for unit transport.

4.3 Unpacking the Unit

Step-by-step instructions for safely unpacking the unit.

4.3.1 Removing the Unit from the Skid with a Forklift

Detailed steps for forklift removal from the skid.

4.3.2 Removing the Unit from the Skid Using Rigging

Detailed steps for using rigging equipment to remove the unit.

4.3.3 Moving the Unit with Piano Jacks

Detailed steps for moving the unit using piano jacks.

5 Piping and Refrigerant Requirements

5.1.1 Field-installed, Gravity-fed Drain Line Requirements

Specifies requirements for gravity-fed drain lines.

5.2 Refrigerant Piping and Charging

Covers all aspects of refrigerant piping, evacuation, and charging.

5.2.1 Refrigerant Piping Guidelines for Air-cooled Systems

Provides guidelines for air-cooled system refrigerant piping.

5.2.2 Refrigerant Line Sizes and Equivalent Lengths

Lists recommended refrigerant line sizes and equivalent lengths.

5.2.3 Refrigerant Charge Requirements for Air-cooled Systems

Details approximate refrigerant charge for air-cooled PDX units.

5.2.7 Superheat and Refrigerant Charge Optimization

Discusses optimizing refrigerant charge for superheat.

5.3 Water/Glycol and Chilled-water Loop Piping Guidelines

Guidelines for water/glycol and chilled water loop piping.

5.3.1 Leak Checking for Unit and Field-installed Piping

Procedures for leak checking unit and field piping.

6 Electrical Connections

6.1 Wye- and Delta-connected Power Supply for PDX and PCW

Covers acceptable power supplies for PDX and PCW units.

7 Checklist for Completed Installation

7.2 Electrical Installation Checks

Verifies all electrical installations meet requirements.

7.3 Piping Installation Checks

Confirms all piping installations are correct and secure.

8 Initial Start-up Checks and Commissioning Procedure for Warranty Inspection

9 Maintenance

9.1 Filters

Details filter types, sizes, and replacement procedures for different models.

9.10 Compressor Maintenance

Covers maintenance procedures for the compressor.

9.10.6 Replacing the Compressor

Step-by-step guide for compressor replacement.

10 Preventive Maintenance Checklist