Covers unit drain requirements, three-phase electrical service, and piping/ductwork planning.
Provides guidelines for transporting units using forklifts or pallet jacks.
Details the steps for removing packaging materials from the unit.
Explains the procedure for safely removing the unit from its skid using a forklift.
Outlines the process for removing the unit from its skid using rigging equipment.
Describes how to move the unit using piano jacks after initial lifting.
Lists required pipe connections for various system types including drain, supply, and refrigerant lines.
Specifies requirements for installing gravity-fed drain lines, including slope and material.
Covers critical safety warnings and procedures for refrigerant piping and system charging.
Provides guidelines for using copper piping, brazing, and nitrogen flow for air-cooled systems.
Lists recommended refrigerant line sizes for standard and digital-scroll models based on equivalent lengths.
Provides approximate R-410A refrigerant charge requirements for air-cooled Liebert PDX units.
Details procedures for evacuating, leak-testing, and charging air-cooled systems with TXV.
Outlines evacuation and charging for systems using the Liebert Lee-Temp™ head-pressure control system.
Describes evacuation and charging for systems with EEV and unheated receivers.
Discusses compressor suction superheat and optimizing refrigerant charge for efficiency.
Provides guidelines and notices for water/glycol and chilled-water loop piping systems.
Recommends isolating units with shutoff valves during leak checking of field-installed piping.
Shows acceptable power supplies by nominal voltage and model for Wye and Delta connections.
Checklist items for verifying supply voltage, wiring connections, grounding, and component rotation.
Checklist items for verifying coolant loop completion, leak checks, piping size, slope, and drain lines.
Covers maintenance for EC fans, including inspection and troubleshooting.
Step-by-step instructions for replacing EC fan modules in downflow models.
Step-by-step instructions for replacing EC fan modules in upflow models.
Covers cleaning the humidifier pan and float switch, and changing humidifier lamps.
Addresses maintenance for steam-generating humidifiers, including canister replacement.
Covers maintenance of condensate drain lines and condensate pumps.
Explains TXV function and how to determine and adjust superheat.
Describes EEV function in controlling superheat and potential instability issues.
Covers compressor oil types, maintenance, burnout, and replacement procedures.
Details the procedure for replacing a compressor, including safety warnings and refrigerant recovery.
Emphasizes maintaining facility water and glycol quality throughout the system's life.
Checklist items for compressors, including oil level, leaks, mounts, wiring, and operation.