AM-HLTMC-OM
Rev AA January 2018
OPPOR Profile
The OPPOR charge profile is used when opportunity charging is desired. It has a start rate of
25% of the batteries rated amp hour capacity, requires one complete charge in every 24 hours
of service and must have an equalize charge done once a week which is programmed to run
automatically.
Operation:
During opportunity charging the user can plug the battery in and charge it during breaks,
lunch or any work stoppage time. Sufficient time should be scheduled after the full charge
to allow the battery to completely cool to ambient temperatures before use.
Complete Charge Time:
This is the time of day for a complete charge.
Note: The factory default complete charge parameters are a 6 hour Equalize every Sunday
at 00 hour.
Block Out Time
This function inhibits the charger from charging the battery during the block out time window. If
a charge cycle has started before the block out window it is inhibited during the block out window
and will automatically restart the charge cycle at the end of the block out window.
Refresh Charging
Refresh or maintenance charging enables the battery to be maintained at maximum charge all
the time that it is connected to the charger.