Suzhou Lily Tech Co., Ltd.
Temperature control working mode
0: R1 up/down limit control
1: External SSR, up/down limit control
2: External SSR, PID control
Temperature hysteresis for R1 (T10 = 0)
Relative to T11, absolute value: T11 - T12
Temperature hysteresis for SSR (T10 = 1)
Relative to T11, absolute value: T11 - T13
Min stop time for temperature load (R1)
High temp. alarm relative point
dis: disable warning. Absolute point = T11 + T21
Low temp. alarm relative point
dis: disable warning. Absolute point = T11 - T22
High temp. protection relative point
dis: disable warning. Absolute point = T11 + T25
Ref.: U20 = 1/2/3, U30 = 1/2/3, U40 = 1/2/3
Absolute point = T11+T25-T26
Ref.: U20 = 1/2/3, U30 = 1/2/3, U40 = 1/2/3
Ti for PID. If Ti = 0, shut integration.
Td for PID. If Td =0, shut differential.
Dehumidify / humidify mode
0: dehumidify, 1: humidify
Relative to H20, absolute value: H20 - H21
Minimum stop time for humidity load (R3)
High humidity warning relative point
dis: disable warning. Absolute point = H20 + H24
Low humidity warning relative point
dis: disable warning. Absolute point = H20 - H25
High humidity protection relative point
dis: disable warning. Absolute point = H20 + H26
Ref.: U20 = 1/2/3, U30 = 1/2/3, U40 = 1/2/3
Absolute point = H20-H26-H27
Ref.: U20 = 1/2/3, U30 = 1/2/3, U40 = 1/2/3
Left turn (R6) time of the timer
Right turn (R7) time unit
Right turn (R7) time of the timer
0: unlimited turning times
Turning motor working mode
0: Either R6 or R7 will be energized.
Need position switches, position arrival shuts off
the power supply to motor
1: Only energized during turning moment (U17).
Manual egg turning support
Motor being energized time for every turning
Effective only when U16 = 1
0: disabled hatching days counting
Output R5 (air exhaustion) control mode
0: Air exhaust
1: Air exhaust + humi./temp. high limit protection
2: Air exhaust + temperature high limit protection
3: Air exhaust + humidity high limit protection
Time unit for air exhaust period (R5)
0: second, 1: minute, 2: hour
Time unit for air exhausting time (R5)
0: second, 1: minute, 2: hour
Output R4 (Lamp or protection) control mode
0: illumination control
1: temperature and humidity high limit protection
2: Temperature high limit protection
3: humidity high limit protection
Output R4 delay time for automatic shutdown
Only effective when U30 = 0
Output R8 (alarm or protection) control mode
0 = alarm output
1 = temperature and humidity High limit protection
2 = temperature high limit protection
3 = humidity high limit protection
0: Normal close, 1: Normal open
0: disable warning, 1: enable warning
PID self auto tune power rate
Percent of heater’s full power rate