IS 678 ECN 4993 Page 7 of 20
Supply Pressures
The appliance is connected directly to the gas supply where the gas supply
pressure is controlled at the source of inlet in the building or via the governor
attached to the bottle gases. See Technical Data for the supply pressures.
Undo the screw and attach a pressure gauge to the boss of the test nipple which is
located on the gas inlet pipe.
Light the oven burner and set thermostat to the highest setting and check the
pressure.
For Propane with a 50mbar supply pressure a governor is required for
adjustment to 37mbar.
(For J10, set each side individually)
Commissioning must include a functional check of all controls and a calibration
check on the thermostat. Oil temperature should be checked once the main
burners have cut out for a second time.
Upon handover, ensure all operators know how to safely light, operate and
shutdown the appliance and are aware of the isolating cock.