IS726 ECN 4530 Page 6 of 10
First Use
Switch on the electricity supplies and leave the boiler to fill for 30 minutes. There is
a delay of 2 minutes for the chiller to come ‘ON’, this will happen every time when
electricity is interrupted.
The unit will display ‘Wait’ whilst it fills and heats/cool. It will display ‘Ready’ when
water can be drawn off.
Touchscreen display configuration
1
3
6
8
10
2
9
5
4
11
7
12
When the boiler is supplied timed mode and clock function are all turned off.
To select these options press the “Power button”, select the feature required and
follow the on-screen instructions.
To adjust the temperature, clock or to perform a boiler descale press “Ready”, select
the option and follow the on-screen instructions.
All units are fitted with a settings PIN lock. Press Ready and then Settings to access
the PIN setting screen. Master PIN code is available from Lincat Service should you
forget the user set PIN.
Filter Replacement
The filter display shows the estimated life remaining in the filter cartridge. A reminder
message is displayed when the filter needs changing.
To replace the filter:
Twist the base of the filter (E) 90 degrees to the left and lower the cartridge out of the
appliance. It will contain a small amount of water. Only use a genuine Lincat Filter.
KEY
Icon Pressing allows
1 Power button On, off, Timed and ECO modes
2 Timed operation
Access to timer settings
3 Clock Access to clock
4 Hot status Status screen
5 Cold status Status screen
6 Status Cold-ready to use/wait
7 Status Hot-ready to use/wait
8 Chiller module Power to chiller module
9 Water in Hot tank water filling
10 Fault F03-Power board error
F04-Power board over temperature
F05-Power board fault
F06-Sensor fault
F07-Heating fault
F08-Thermistor fault
F09-Water supply fault
F10-Chiller condenser over heat
F11-Chiller- clean condenser
11 Element Element ON
12 Filter Filter life status