H
hannahandersonAug 7, 2025
What to do if there is no automatic control box cooling in Lincoln 1162-080-A?
- DdonnatravisAug 7, 2025
If there is no automatic control box cooling in your Lincoln Oven, begin by checking the circuit breakers and resetting them if needed. Make sure the power plug is firmly in the receptacle and measure the incoming power supply, calling the power company if necessary. Inspect the cooling fan thermostat (it closes at 120°F and opens at 100°F). With the cooling fan thermostat pre-heated, check for continuity; if the switch is open, replace the thermostat. Check for 120VAC at the cooling fan. If no voltage is present, trace the wiring back to the cooling fan thermostat. If voltage is present, and the motor doesn't run, check for opens, shorts, or grounds. With the power off, check for a locked rotor.