Description Lights up if ... Possible reason(s) Action(s)
Emergency stop
one of the (Emergency stop)
buttons has been pushed.
The shredder will switch off
completely.
Remove danger.
Restart the shredder.
Fault
an error in the system can be
read out via alarm on the
operating panel
Error on the operating panel
=> delete alarm and
acknowledge error with the
button "Acknowledge error".
If the error cannot be
acknowledged, please contact
Lindner service.
Hydraulic system
temperature
the hydraulic oil is too hot. Oil cooler soiled.
Ambient temperature
so high that the
cooling capacity is not
sufficient.
The shredder switches off
automatic operation. Motor
continues to run in idle and
cools down oil until message
fades.
After cooling down, the
automatic system can be
restarted.
Maintenance
the maintenance must be
performed "every 250
hours".
Perform the Maintenance of
the engine "every 250 hours"
Oil filter
there is negative pressure in
the hydraulic oil filter.
Hydraulic oil filter
clogged.
Hydraulic oil viscosity
is too high.
Note: In the case of a cold
start, this message may
light up from time to time.
If this message is shown
longer than 15 min: replace all
hydraulic oil filters on the
machine.
Do not restart the machine
after an automatic switch off
(indicator light lit for 30
minutes), all hydraulic oil filters
must be replaced!
Air filter the air intake is insufficient. Air filter clogged. Clean or replace air filter.