Error codes
During operation when an error occurs the board will use the led’s to indicate where the problem
exists.
For motor specic faults the green led will blink 1 time for motor 1, and 2 times for motor 2. The red
led will blink from 2 to 9 times depending on the error code.
The error codes are as follows:
2 Battery drop out: Battery capacity low enough to drop below 6 volts while running
3 Low battery: Voltage below 8 volts at start of cycle
4 High battery: Voltage greater than 18 volts
5 Excessive motor current: High amperage, also indicated by 1 side of slide continually stalling.
6 Motor short circuit: Motor or wiring to motor has shorted out.
8 Hall signal not present: Encoder is not providing a signal. Usually a wiring problem.
9 Hall power short to ground: Power to encoder has been shorted to ground. Usually a wiring
problem.
When an error code is present, the board needs to be re-set. Energizing the extend/retract switch
resets the board. Energize the extend/retract switch again for normal operation.
WARNING!
DO NOT MOVE THE RV UNLESS THE MOTORS ARE PLUGGED IN!
revWNBG2
Question and Answer IconNeed help?

Do you have a question about the Lippert Components 13398-C and is the answer not in the manual?

Lippert Components 13398-C Specifications

General IconGeneral
BrandLippert Components
Model13398-C
CategoryController
LanguageEnglish

Summary

Error Codes Explained

Manual Override Procedures

Electronic Manual Override

Procedure for electronic manual override using the mode button on newer board revisions.

Manual Slide Retraction

Steps to disengage motors, manually retract the slide room, and secure it for travel.

Troubleshooting Flow Chart

Detailed Troubleshooting Steps

Checking Fuses and Obstructions

Guidance on checking fuses and identifying obstructions for slide room issues.

Low Voltage and Single Side Movement

Troubleshooting low battery voltage and issues with only one side of the slide moving.

Manual Movement and Debris Check

Instructions for manually moving the slide and checking for debris in the gear rack.

Status LED Diagnosis

Checking status LED lights when the slide direction switch is actuated.

Related product manuals