TROUBLESHOOTING – CHECKING FOR BAD CYLINDER
1. Retract (close) the slideout (room) completely.
2. Loosen hose from “E” (extend) port on the manifold of the Power Unit.
WARNING- Do not attempt to run room out with the “E” port hose loose. The
system will experience RAPID FLUID LOSS.
3. Plug opening on manifold to prevent drawing air into the system.
4. Energize the Power Unit to retract (close) room.
5. Continue to run the room in and watch for fluid flow from hose/port
“E”. Fluid flow greater than a few drops will indicate internal cylinder
leaking (bypassing of piston seal). If there is no fluid flow, reconnect
hose to “E” port and tighten.
WARNING - Be sure to reconnect and tighten hose at the “E” port before
attempting to extend (open) the room or the system will experience RAPID
FLUID LOSS.
Contact qualified technician if there is excessive fluid flow. The cylinder should
not be repaired in the field.
Refill the Power Unit Reservoir as recommended on Page 10 of this manual.
12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lippert Components HYDRAULIC SLIDEOUT SYSTEM and is the answer not in the manual?

Lippert Components HYDRAULIC SLIDEOUT SYSTEM Specifications

General IconGeneral
BrandLippert Components
ModelHYDRAULIC SLIDEOUT SYSTEM
CategoryMotorhomes
LanguageEnglish

Related product manuals