12/15/2022
10
TROUBLESHOOTING ELECTRICAL
Testing for signal compromise through
system to various components.
• Wiring
o Battery
• Components
o Circuit Breaker/Fuse
o Controller
o Solenoid (Ext/Ret)
o Motor
o Coils
Error Code
Low Voltage
ERROR CODES
Touch Panel
Message
What’s Happening? What Should Be Done?
“EXCESS ANGLE”
Unsecured controller.
Uneven or sloped site.
Check and secure controller placement.
Relocate the trailer.
“EXCESSIVE ANGLE”
Controller not properly secured.
Excessive angle reached during manual operation.
Check and secure controller placement.
Relocate the coach.
“BAD CALIBRATION” Sensor calibration values are out of range. Replace controller.
“FEATURE DISABLED”
Hitch recognition requested but no hitch height set.
Zero point not set.
Perform "AUTO LEVEL" sequence to establish hitch height.
Set zero point.
“LOW VOLTAGE”
Bad connection or wiring.
Discharged or bad battery.
Check wiring – repair or replace.
Test battery voltage under load – charge or replace.
“OUT OF STROKE”
Unsecured controller.
Uneven or sloped site.
Check and secure controller placement.
Relocate the trailer.
“EXTERNAL SENSOR” Bad connection or wiring. Replace or repair connection to rear remote sensor.
“JACK TIME OUT” System could not level in expected time.
Check for obstructions, leaks, fluid level and voltage to power unit motor under
load.
“AUTO LEVEL FAIL”
Unsecured controller.
Voltage drop.
Check and secure controller placement.
Test battery voltage under load – charge or replace.
“FUNCTION ABORTED” User has aborted an automatic leveling sequence. Restart the sequence.
19
20