    What to do if there is no flow through Liquid Controls M-10 Measuring Instruments?
    • J
      joecollierAug 17, 2025
      If your Liquid Controls Measuring Instruments meter is not flowing any product, there might be a few reasons. It could be due to a faulty or non-functioning pump, a valve that is not open or not working correctly, or the meter might be 'frozen' because of chemical 'salts' or foreign material buildup inside the metering chamber. Consider cleaning the meter and inspecting for any damage.
  • A
    Anna RichardsAug 19, 2025
    How to fix if Liquid Controls M-10 meter counts down in reverse?
    • J
      Jennifer StuartAug 19, 2025
      If your Liquid Controls Measuring Instruments meter counts down in reverse, you should reverse the direction of flow by reversing the adjuster drive gear.
  • H
    hannahgeorgeAug 22, 2025
    Why is my Liquid Controls M-10 meter running too slowly?
    • S
      smithrobinAug 22, 2025
      If your Liquid Controls Measuring Instruments meter runs too slowly, several factors could be the cause. The valve's internal mechanism might be faulty, preventing it from fully opening. Also, the meter gears or rotors could be partially 'salted', which slows down the rotation of parts. Cleaning the meter might help. Another potential cause could be a downstream restriction or a clogged strainer basket.
  • S
    Shane CopelandAug 25, 2025
    How to stop leakage from the cover gasket on Liquid Controls Measuring Instruments?
    • A
      amandaharrisonAug 26, 2025
      If you observe leakage from the cover gasket of your Liquid Controls Measuring Instruments, it might be because the gasket has been damaged due to shock pressure, or the cover bolts haven't been tightened sufficiently. Replace the gasket and ensure the cover bolts are correctly tightened.
  • M
    Marc NovakAug 27, 2025
    How to fix leakage past packing gland drive shaft housing in Liquid Controls M-10?
    • K
      Kari CarterAug 27, 2025
      If you notice leakage past the packing gland drive shaft housing from the internal metering chamber in your Liquid Controls Measuring Instruments, it's likely that the internal seal of the packing gland assembly is worn. Replace the packing gland and O-ring seal.
  • C
    Christopher MercadoAug 30, 2025
    Why are teeth breaking on timing gears in Liquid Controls Measuring Instruments?
    • K
      Kristen SnyderAug 30, 2025
      If the teeth on the timing gears of your Liquid Controls Measuring Instruments are breaking, it could be due to starting or stopping the flow in the meter too rapidly, or the pump bypass not being adjusted properly.
  • A
    amanda26Sep 2, 2025
    How to fix the Liquid Controls Measuring Instruments when it counts down in reverse?
    • C
      Cynthia WeberSep 2, 2025
      If the Liquid Controls Measuring Instruments meter counts down in reverse, reverse the direction of flow by reversing the adjuster drive gear.
  • C
    Charles EvansSep 4, 2025
    What to do if there is leakage from the cover gasket of Liquid Controls Measuring Instruments?
    • E
      Edward MurraySep 4, 2025
      If you observe leakage from the cover gasket of your Liquid Controls Measuring Instruments, it's likely that the gasket has been damaged due to shock pressure or the cover bolts haven't been tightened sufficiently. Replace the gasket and ensure the cover bolts are correctly tightened.
  • D
    David MontgomerySep 7, 2025
    Why is there no flow through my Liquid Controls Measuring Instruments?
    • K
      Kimberly ShermanSep 8, 2025
      If the Liquid Controls Measuring Instruments has no flow, this could be due to a faulty non-functioning pump or a valve that is not open or not functioning.
  • C
    curryheatherSep 10, 2025
    What to do if product flows through Liquid Controls M-10 but the register doesn't operate?
    • T
      Tammy BrownSep 12, 2025
      If product flows through the Liquid Controls Measuring Instruments meter but the register does not operate, check the packing gland and gear train. A faulty register should be checked and repaired by a trained mechanic. Also, replace the packing gland, as this may be caused by starting the flow too rapidly.

Summary

M & MA Series Meters

Safety Procedures

BE PREPARED

Crucial safety instructions before operating the meter, emphasizing qualified personnel and proper procedures.

SAFELY EVACUATE PIPING SYSTEM

Procedures for safely relieving internal pressures and draining all liquid from the system before disassembly.

Installation & Operation

Installation Requirements

Essential requirements for installing the meter, including safety precautions, codes, and piping considerations.

Operation Requirements

Guidelines for operating the meter, emphasizing keeping it full of product and managing piping for optimal performance.

Meter Start Up and Operation

Cautions and procedures for safely starting up and operating the meter, including priming and pressure limits.

Reversing the Meter Registration

Setting the Standard Adjuster

Maintenance

Maintenance Requirements

Key considerations for meter maintenance, including preventing pipe strain and seasonal storage procedures.

Disassembling the Meter

Reassembling the Meter

Troubleshooting

Liquid Controls M-10 Specifications

General IconGeneral
ModelM-10
CategoryMeasuring Instruments
Meter Body MaterialAluminum
Accuracy±0.5% of reading
Maximum Operating Pressure150 psi