14
2.8.2 Installing Input Fuses
Installing fuses on the drive input side is recommended to prevent internal short circuit. Select
the suitable fuses below or the branch circuit protection in compliance with local electrician
regulations.
400V Model Three Phase
Input Current I (A)
Line Fuse
I (A)
Bussmann P/N
0.4kW (0.5 HP)
2.7
5
FRS-R-5
0.75kW (1 HP)
4.4
10
FRS-R-10
1.5kW (2 HP)
6.7
10
FRS-R-10
2.2kW (3 HP)
9.3
15
FRS-R-15
3.7kW (5 HP)
12.9
20
FRS-R-20
200V Model Single phase
Input Current I (A)
Line Fuse
I (A)
Bussmann P/N
0.2kW (0.25 HP)
3.6
6
FRS-R-6
0.4kW (0.5 HP)
7.4
10
FRS-R-10
0.75kW (1 HP)
13.5
20
FRS-R-20
1.5kW (2 HP)
24
30
FRS-R-30
2.2kW (3 HP)
33
40
FRS-R-40
200V Model Three Phase
Input Current I (A)
Line Fuse
I (A)
Bussmann P/N
0.2kW (0.25 HP)
2.2
5
FRS-R-5
0.4kW (0.5 HP)
3.7
5
FRS-R-5
0.75kW (1 HP)
6.6
10
FRS-R-10
1.5kW (2 HP)
10.5
15
FRS-R-15
2.2kW (3 HP)
14.8
20
FRS-R-20
3.7kW (5 HP)
21.5
30
FRS-R-30

Other manuals for LiteOn EVO6000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LiteOn EVO6000 Series and is the answer not in the manual?

LiteOn EVO6000 Series Specifications

General IconGeneral
BrandLiteOn
ModelEVO6000 Series
CategoryController
LanguageEnglish

Related product manuals