12E Series Euent Pump
OWNER'S MANUAL
English
EN
This submersible pump is designed for use in basins or pumping stations and is suitable for pumping clean
water or effluent gray water with up to 3/4" (19 mm) spherical semi-solids. Do not use the pump in appli-
cations where sewage or any other debris (gravel, sand, floating debris, etc.), abrasives, or corrosives are
present.
The pump motor is equipped with an automatic restart thermal protector and
may restart unexpectedly. Activation of the thermal protector indicates that the
motor is overloaded or overheated, which may be due to application problems,
such as a clogged pump impeller, a switch stuck in the on position, a dry running
of the pump, a air-sealed pump, a short pump cycle, an excessively high or low
voltage supply, or a pump, motor, bearings, or seal that may have reached the
end of its useful life.
This product is covered by a Limited Warranty for a period of 36 months from the
date of original purchase by the consumer. For complete warranty information,
refer to www.LittleGiant.com
.
Specifications
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar with
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with
national and local electrical and plumbing codes and within Little Giant recommendations may result in
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product’s application, limitations, and potential hazards. Read and follow instructions carefully to
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following
hazards:
Model HP Volts Hz
Amps
Watts ON Level
OFF
Level
FLA Start
12E-CIM
1/2 115 60 10 18 1100
N/A N/A
12E-CIA-RF 12” - 15” 6” - 8”
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri-
cally disconnected.
If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of
power.
If the disconnect panel is not accessible, contact the electric company to stop service.

Questions and Answers

  • M
    Michael AcostaJul 29, 2025
    What to do if Little Giant 12E runs but does not discharge liquid?
    • R
      racheljenkinsJul 29, 2025
      If your Little Giant Water Pump is running but not discharging liquid, there might be several reasons. First, the check valve might be installed backward; ensure the flow indicating arrow on the check valve body indicates proper installation. The check valve could also be stuck or plugged, so remove it and inspect its operation. Other potential issues include the lift being too high for the pump (check the rated pump performance), the inlet to the impeller being plugged (pull the pump and clean it), or the pump being air locked (remove the pump and clean the air bleed hole).
  • J
    James WilliamsAug 3, 2025
    Why Little Giant Water Pump does not turn on?
    • E
      edwingillAug 4, 2025
      If your Little Giant Water Pump doesn't turn on, there are several potential causes. Ensure the pump is properly plugged in. Check the circuit breaker to see if it's off, and turn it on, or replace the fuse if it's removed. Also, verify that there isn't an accumulation of trash on the float; if there is, clean it. Furthermore, check for any obstructions in the float path and provide clearance. If these steps don't resolve the issue, the switch or motor might be defective, requiring you to replace the switch or the entire pump.
  • A
    Amy JordanAug 9, 2025
    What to do if Little Giant 12E Water Pump will not shut off?
    • M
      mackstevenAug 9, 2025
      If your Little Giant Water Pump will not shut off, it could be due to a few reasons. The float or float rod might be obstructed, so check their path and provide clearance. The pump could also be air locked; remove the pump and clean the air bleed hole. If the liquid inflow matches the pump capacity, a larger pump may be required. Lastly, a defective switch could be the cause, necessitating a replacement.
  • T
    tmcbrideAug 15, 2025
    How to troubleshoot Little Giant Water Pump not delivering rated capacity?
    • D
      Danielle HicksAug 16, 2025
      If your Little Giant Water Pump does not deliver its rated capacity, several factors could be responsible. The lift might be too high for the pump, so check the rated pump performance. Low voltage could be causing the speed to be too slow; ensure the supply voltage matches the nameplate rating. A clogged impeller or discharge pipe could also be the issue; pull the pump and clean it, and check the pipe for scale or corrosion. Finally, impeller wear due to abrasives could be the cause, which would necessitate replacing the pump.
  • E
    Edward ChavezAug 21, 2025
    Why Little Giant 12E cycles continuously?
    • G
      greenenormaAug 22, 2025
      If your Little Giant Water Pump cycles continuously, several factors could be the cause. A missing check valve in a long discharge pipe might be allowing liquid to drain back into the basin; in this case, install a check valve in the discharge line. A leaking check valve could also be the problem; inspect it for correct operation. Alternatively, the basin might be too small for the inflow; consider installing a larger basin.

Summary

Specifications

SAFETY INSTRUCTIONS

DANGER: Risk of death, personal injury, or property damage

Critical safety warning regarding explosion, fire, or electric shock hazards.

SAFETY INSTRUCTIONS

WARNING: High voltages capable of causing severe injury or death

Warnings about electrical shock hazards and proper grounding procedures.

CAUTION: Risk of bodily injury, electric shock, or equipment damage

Cautions regarding misuse by children, automatic starts, and dry running.

NOTICE: Risk of damage to pump or other equipment

Notices concerning pumping incompatible liquids and dry running damage.

INSTALLATION

Typical Installation

Diagram and components for a typical pump installation in a basin.

Physical Installation

Detailed steps and considerations for physically installing the pump.

OPERATION TESTING

Electrical Connections

Guidelines for connecting the pump to a power source, including GFCI use.

Testing Automatic Pump Operation

Steps to test the pump's automatic operation with a float switch.

Testing Manual Pump Operation

Procedures for testing the pump in manual continuous operation mode.

MAINTENANCE

Periodic Service

Recommended schedule and checks for routine pump maintenance.

Cleaning Impeller and Volute

Instructions for disassembling, cleaning, and reassembling pump components.

Troubleshooting

Problem;Probable Causes;Corrective Action

Common issues, their likely causes, and recommended solutions.

Little Giant 12E Series Specifications

General IconGeneral
BrandLittle Giant
Model12E Series
CategoryWater Pump
LanguageEnglish

Related product manuals