AT+NAME=xxxxx “xxxxx” is a character string with a maxi-
mal length of 16.
AT+NAME? Inquire the name of the local adapter.
AT+PIN Specify a PIN. The default PIN is“1234”.
Paired adapters should have a same PIN.
AT+PIN=xxxx “xxxx” is a 4-8 digit string.
AT+PIN- Cancel authentication by PIN.
AT+PIN? Inquire the current PIN.
AT+RCFG Enables/disable remote conguration from
a remote device by executing the remote
access handshaking protocol.
AT+RCFG+ Enables remote conguration.
AT+RCFG- (default) Disables remote conguration.
AT+RCFG? Inquire the current setting
AT+DCOV Specify whether the adapter can be
discovered by remote device.
AT+DCOV+ (default) Device is in discoverable state.
AT+DCOV- Device is non discoverable.
AT+DCOV? Inquire the current discoverability status.
AT+RESP Specify whether result messages are
prompted when AT commands are execut-
ed. The result messages are: OK/ERROR
for command execution, or CONNECT/
DISCONNECT for connection status.
12