The table below shows a list of the parameters and values used by the Logitrans controller and the
equipment needed to read and/or set them.
A: Thevaluescanbereadonadisplay/batteryindicatorttedtothetruck(PantherMAXI/SELF).
B: The parameters/values can be set/read by means of a hand terminal.
C: The parameters/values can be set/read by means of a PC.
D: Thevalueisfactory-setasstandardonPantherMINI/MAXI
E: Thevalueisfactory-setasstandardonSELF.
Parameter (can be set) Text in hand terminal A B C D E
1 Max. speed Maximum speed X X 100% 100%
2 1st. reduced speed 1. reduced speed X X 100% 34,5%
3 2nd. reduced speed 2. reduced speed X X 34,5% 34,5%
4 Minimum output X 9,8% 9,8%
5 Safety forward output X 49,8% 49,8%
6 Max. current Maximum current X X 200A 200A
7 Acceleration slope Acc. slope X X 1,50s 3,00s
8 Max. temperature X 74°C 74°C
9 Safety forward time X 5,0s 5,0s
10 Battery 90% Battery 90% X X 24,14V 24,14V
11 Battery 70% Battery 70% X X 23,84V 23,84V
12 Battery 50% Battery 50% X X 23,54V 23,54V
13 Battery 25% Battery 25% X X 23,24V 23,24V
14 Battery 15% Battery 15% X X 22,95V 22,95V
15 Battery charging voltage X 27,52V 27,52V
16 A/D start voltage X 2,35V 2,35V
17 A/D 100% voltage X 1,82V 1,82V
Value (cannot be set) Text in hand terminal A B C
18 Total hours Total hours X X X
19 Subtotal hours Subtotal hours X X X
20 No of charges No of charges X X
21 No of discharges No of discharges X X
22 Serial no. X
23 Programme version X
24 Memory X
25 Error counters X
26 Error messages X
27 Battery meter X
Electric system Electronic control Logitrans Controller