8
Standby
Regulated reverse
Handle tilted. Control ready to operate.
Safetyforwardisactivated(bellyswitch)
Hall inputs defective : There can be a lead defect. Check that the message is displayed even
when the battery current is too low.
Memory fault : Check the operating parameters with the PC program.
Motor protector, current limitation: Motor overloaded. After a short pause, operation can be
restarted. If appropriate, check the parameter Maximum current in the PC program.
Motor control overheat : Motor overloaded. After a pause of a few minutes, operation can be
restarted. If appropriate, check the operating parameter Maximum temp in the PC program.
Motor control defective : Replace.
Regulated FORWARD
Operating messages in mini-display for Logitrans Controller
PC program connected
100% reverse
100% FORWARD
Electronic control - Operating messages Electric system
Motor control defective : Replace.