General characteristics
127V - 60 Hz
Supply voltage ..............................................................................127V AC
Frequency ........................................................................................60 Hz
Intensity consumed .............................................................................10A
Power consumed ...................................................................1.200 Watts
Ceramic fuses ................................................................................T12.5A
100V - 60 Hz
Supply voltage ..............................................................................100V AC
Frequency ........................................................................................60 Hz
Intensity consumed .......................................................................... 12.5A
Power consumede ................................................................. 1.250 Watts
Ceramic fuses ...................................................................................T20A
100V - 50 Hz
Supply voltage ..............................................................................100V AC
Frequency .........................................................................................50Hz
Intensity consumed .......................................................................... 12.5A
Power consumed ...................................................................1.000 Watts
Ceramic fuses ...................................................................................T20A
Electrical properties
Dimensions: Length x width x height ............................ 60 x 46 x 210 cm
Net weight .........................................................................................90 kg
Maximum set depression ............................................69 kPa (690 mbar)
Fuses ........................................................................................ Time-delay
.........................................................................................Size 6.3 x 32 mm
Cooling ....... By way of mechanical ventilation incorporated in the pump
Protection index ................................................................................ IP 20
Electrical protection class .......................................................................1
Operating temperature ..........................+10°C to +30°C (+50°F to +86°F)
Storage temperature ............................. -20°C to +70°C (-4°F to +158°F)
Unit fitted with patented treatment heads.
The Cellu M6 Keymodule [2] i is marked as a medical device by virtue of
Annex V of regulation 93/42/EEC (standards 60601-1-1 and 60601-1-2).
!
Please consult Customer Services regarding other voltages.
Electrical properties
230V - 50 Hz
Supply voltage .............................................................................230V AC
Frequency ........................................................................................50 Hz
Intensity consumed ..............................................................................4A
Power consumed .....................................................................920 Watts
Ceramic fuses ....................................................................................T8A
220V - 60 Hz
Supply voltage ..............................................................................220V AC
Frequency ........................................................................................60 Hz
Intensity consumed ............................................................................4.8A
Power consumed ...................................................................1.100 Watts
Ceramic fuses .....................................................................................T8A
6