EasyManuals Logo

LS tractor R4047 User Manual

LS tractor R4047
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
Air-bleeding from Fuel injection pump
1. Turn key switch to the “ON” position.
2. Loosen the air-bleed bolt by using a spanner and
turn it by hands until it stops.
3. If clean fuel without bubbles comes out, turn the
key switch to “OFF” position and tighten the air-
bleed bolt.
Tightening torque : 19.6~29.4 N.m
(14.54~21.81 lb-ft)
Cover the bleeding fuel with a rag so that it does not flow to other components.
Notice
Air bleed bolt
Notice
5
5 5
5 - 26

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LS tractor R4047 and is the answer not in the manual?

LS tractor R4047 Specifications

General IconGeneral
BrandLS tractor
ModelR4047
CategoryTractor
LanguageEnglish

Related product manuals