Installation Considerations
• Selecting the installation site
- The location must be free from vibration, and the inverter must be installed on a wall that can support the inverter’s weight.
- The inverter can become very hot during operation. Install the inverter on a surface that is fire-resistant or flame-retardant
and with sufficient clearance around the inverter to allow air to circulate.
• The illustrations below detail the required installation clearances. The inverter can become very hot during operation.
Install the inverter on a surface that is fire-resistant or flame-retardant and with sufficient clearance around the inverter to
allow air to circulate. The illustrations below detail the required installation clearances.
• If you are installing multiple inverters in one location, arrange them side-by-side and remove the top covers.
The top covers MUST be removed for side-by-side installations. Use a flat head screwdriver to remove the top covers.
(DIN rail installation is available.)
Installation Quick Guide
Installation Site Air Circulation Precaution Side-by-side Installation
Manual Download
For detailed information on installation and commissioning,
full version of the G100 manual can be downloaded at www.lsis.com
LSLV
0022 G100 2
SNFOE
Motor Capacity
Series Name
Input Voltage
Keypad
UL Type
EMC Filter
DC Reactor
I /O
0001 - 0.1kW
0002 - 0.2kW
0004 - 0.4kW
0008 - 0.75kW
0015 - 1.5kW
0022 - 2.2kW
2~3 Single phase 200V - 240V
E - LED keypad
O - UL open type
F - Built-in EMC filter[C2]
//PO3FBDUPS
S - Standard A - Advanced
2mm
2mm
2”
minimum
2” minimum
2”
minimum
4”
minimum
4”
minimum
LSIS Co., Ltd. |
01
Verify & Identify the Delivery
• Inspect the drive for any damanage. If the drive
appearsdamage upon receipt, contact your supplier.
• Verify receipt of the correct model by checking the information
on thenameplate as shown below. If you have received the
wrong model,contact your supplier.
(The nameplate is on the side of the product.)
LSLV0022G100-2EOFNS
INPUT 200-240V 3Phase 50/60Hz
HD: 11.8A ND: 13.1A
OUTPUT 0-Input V 3Phase 0.01-400Hz
HD: 11A ND: 12A
4.2kVA IP: 20
Ser. No 5501406001F
Inspected by D. K. YU