EasyManua.ls Logo

LSIS SV008iG5A-2 User Manual

LSIS SV008iG5A-2
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Questions and Answers:

LSIS SV008iG5A-2 Specifications

General IconGeneral
BrandLSIS
ModelSV008iG5A-2
CategoryInverter
LanguageEnglish

Summary

Chapter 1: Basic Information & Precautions

1.1 Important Precautions

Provides general information and precautions for safe use of the SV-iG5A series inverter.

Chapter 2: Installation & Wiring

2.1 Installation Precautions

Safety and environmental guidelines for installing the inverter, including ventilation and clearances.

2.3 Terminal Wiring (Control I/O)

Details the control I/O terminal assignments and descriptions for inverter functions.

Chapter 3: Basic Configuration

Chapter 4: Programming Keypad & Basic Operation

4.5 Parameter Setting

Guides users on how to set and adjust parameter values in the Drive Group.

4.7 Frequency Setting and Basic Operation

Details frequency setting methods via keypad and terminals, and basic operation steps.

Chapter 7: Basic Functions

7.1 Frequency Mode

Explains different methods for setting the operating frequency (keypad, analog, RS485).

7.2 Multi-Step Frequency Setting

Details how to configure multiple preset frequencies for stepped operation.

7.3 Operating Command Setting Method

Describes how to set the drive mode and operating commands via keypad or terminals.

7.4 Accel/Decel Time and Pattern Setting

Guides on setting acceleration, deceleration times, and curve patterns.

7.5 V/F Control

Explains different V/F patterns (Linear, Square, User V/F) for voltage-frequency control.

7.6 Stop Method Select

Details options for stopping the motor: Decel to Stop, DC Braking, and Free Run.

7.7 Frequency Limit

Explains how to set frequency limits using Max/Start frequency and high/low limits.

Chapter 8: Advanced Functions

8.1 DC Brake

Details functions for stopping the motor using DC braking methods.

8.2 Jog Operation

Explains how to perform low-speed jogging operation using terminals or keypad.

8.7 PID Control

Guides on configuring PID control for precise regulation of process variables.

8.8 Auto-tuning

Describes the process of automatic motor parameter measurement for optimal performance.

8.9 Sensorless Vector Control

Details the setup and operation of sensorless vector control for motor speed regulation.

8.11 Speed Search

Describes the speed search function to prevent faults when power is restored after a load.

8.17 Overvoltage Protection and Power Braking

Describes functions to prevent overvoltage during deceleration and power braking.

8.18 External Brake Control

Details controlling an external brake system based on frequency and current.

8.24 Parameter Read/Write

Instructions for reading and writing inverter parameters using a remote keypad.

8.25 Parameter Initialize and Lock

Guides on initializing parameters to factory defaults and setting parameter lock.

Chapter 9: Monitoring

9.3 Monitoring Fault Condition

Guides on checking current fault status and accessing fault history information.

Chapter 10: Protective Functions

10.1 Electronic Thermal

Describes the electronic thermal protection for the motor against overheating.

10.2 Overload Warning and Trip

Explains overload warning levels and trip functions to protect the motor from excess current.

Chapter 12: Troubleshooting & Maintenance

12.2 Fault Remedy

Provides causes and remedies for various inverter faults indicated on the keypad.

12.3 Precautions for Maintenance and Inspection

Safety warnings and precautions to follow before and during inverter maintenance.

Recommended Installation Instructions