LSIS SV055iG5A-4 User Manual

LSIS SV055iG5A-4
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Questions and Answers:

LSIS SV055iG5A-4 Specifications

General IconGeneral
Rated Power (kW)5.5
Cooling MethodForced air cooling
AltitudeUp to 1000m without derating
Enclosure RatingIP20
Input Voltage380-480V
Output Voltage380-480V
Output Frequency0.1-400 Hz
Efficiency97%
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating
Operating Temperature-10 ~ 50°C
Storage Temperature-20 to 65°C
Humidity5 to 95% RH (non-condensing)

Summary

Chapter 1 - Basic Information & Precautions

1.1 Important Precautions

General safety and handling advice for the inverter, including unpacking and inspection.

Chapter 2 - Installation & Wiring

2.1 Installation Precautions

Guidelines for safe and proper inverter installation, including clearances, environment, and mounting.

2.3 Terminal Wiring (Control I/O)

Details the function and connection of control signal terminals on the inverter.

2.4 Specifications for Power Terminal Block Wiring

Specifies wire sizes, screw types, and torque for power terminal connections.

Chapter 4 - Programming Keypad & Basic Operation

4.1 Keypad Features

Explains the function of each key and LED display on the inverter's keypad.

4.5 Parameter Setting

Guides on how to set specific parameter values, like acceleration time and frequency.

4.7 Frequency Setting and Basic Operation

Explains how to set operating frequency via keypad and terminals for basic inverter control.

Chapter 5 - Function List

Chapter 7 - Basic Functions

7.1 Frequency Mode

Explains how to select the frequency input method (keypad, analog, RS485).

7.3 Operating Command Setting Method

Covers setting run commands and motor direction via keypad, terminals, or communication.

7.4 Accel/Decel Time and Pattern Setting

How to set acceleration/deceleration times and S-curve patterns for smooth motor control.

7.5 V/F Control

Explains different V/F patterns (Linear, Square, User V/F) for voltage-frequency control.

7.6 Stop Method Select

Describes how to configure the inverter's stop behavior (Decel, DC Brake, Free Run).

Chapter 8 - Advanced Functions

8.1 DC Brake

Configuration for DC injection braking for stopping the motor or holding it.

8.7 PID Control

Setup and configuration for using the inverter's PID controller for closed-loop control.

8.8 Auto-tuning

Procedure for automatically measuring motor parameters for optimized performance.

8.9 Sensorless Vector Control

How to enable and configure sensorless vector control for improved torque and speed response.

8.15 Self-Diagnostic Function

Performing self-checks for IGBT, output, and ground faults without disconnecting wiring.

8.25 Parameter Initialize / Lock

Resetting parameters to factory defaults or setting a password to lock parameters.

Chapter 9 - Monitoring

9.3 Monitoring Fault Condition

Viewing current faults and accessing fault history logged by the inverter.

Chapter 10 - Protective Functions

10.1 Electronic Thermal

Configuring electronic thermal protection for the motor based on current and motor type.

10.2 Overload Warning and Trip

Setting warning and trip levels for motor overload conditions.

10.3 Stall Prevention

Enabling and configuring stall prevention during acceleration, constant run, or deceleration.

10.4 Output Phase Loss Protection

Setting up protection against output phase loss for motor and inverter safety.

Chapter 12 - Troubleshooting & Maintenance

12.1 Protective Functions

Lists protective functions, their keypad display codes, and descriptions of faults.

12.2 Fault Remedy

Provides causes and remedies for various inverter faults displayed on the keypad.

12.3 Precautions for Maintenance and Inspection

Safety warnings and precautions to be followed during maintenance and inspection.

Related product manuals