Chapter 7 Analog Input Module (XBF-AD08A)
7.10 Register U devices
The variables for each module are automatically registered by referring to the information of the
special modules set up in the [I/O Parameter]. User can modify variables and descriptions.
(1) Registration Procedure
(a) In [I/O Parameter], set up special module in slot.
(b) Double click [Variables/Comment].
(c) In the ‘Edit’ menu, select ‘U-Device Auto Registration
(special module variable auto registration).
7 - 23