EasyManua.ls Logo

LSIS XBF-DC04A User Manual

LSIS XBF-DC04A
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Right choice for ultimate yield
LSIS strives to maximize customers' profit in gratitude of choosing us for your partner.
Programmable Logic Controller
XGB Analog
Users Manual
Read this manual carefully before
installing,
wiring, operating, servicing
or inspecting this equipment.
Keep this manual within easy reach
for quick reference.
XGT Series
www.lsis.com
XBF-AD04A
XBF-AD08A
XBF-DV04A
XBF-DC04A
XBF-RD04A
XBF-TC04S
XBF-AH04A
XBO-AD02A
XBO-DA02A
XBO-AH02A
XBO-RD01A
XBO-TC02A
Analog
input
Analog
output
Temperature input
Analog
input/output
Analog
input option board
Analog
output option board
Analog
input/output option board
Temperature input
option board
Built
-in PID

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the LSIS XBF-DC04A and is the answer not in the manual?

LSIS XBF-DC04A Specifications

General IconGeneral
BrandLSIS
ModelXBF-DC04A
CategoryController
LanguageEnglish

Summary

Safety Instructions

Safety Instructions for design process

Guidelines and warnings for designing systems using PLCs, focusing on protection circuits and overload prevention.

Safety Instructions on installation process

Precautions for safely installing PLC modules, including environment, power, and physical contact.

Safety Instructions for wiring process

Crucial safety guidelines for wiring PLC modules, emphasizing power disconnection and secure connections.

Safety Instructions for test-operation and maintenance

Safety measures for testing, operating, and maintaining PLC equipment, including power handling and battery safety.

Chapter 1 General

Chapter 2 Analog Input Module (XBF-AD04A)

2.1 Setting Sequence before operation

Step-by-step guide for the initial setup and operation of the XBF-AD04A analog input module.

2.2 Specifications

Detailed performance specifications for the XBF-AD04A analog input module, covering environmental and physical characteristics.

2.3 Name of part and function

Identification and description of the physical parts and their functions on the XBF-AD04A analog input module.

2.4 Characteristic of I/O conversion

Explanation of the I/O conversion characteristics for the XBF-AD04A module, illustrating the relationship between analog input and digital output.

2.5 Conversion Characteristic according to Input Range

Details the conversion characteristics based on different input ranges for voltage and current, with specific data formats.

2.6 Accuracy

Information on the accuracy of the XBF-AD04A module, specifying the digital output variation relative to input range.

2.7 Functions of Analog Input Module

Overview of the functions of the XBF-AD04A analog input module, including channel control, range settings, and conversion methods.

2.8 Wiring

Precautions and examples for correctly wiring the XBF-AD04A analog input module to external devices.

2.9 Operation Parameter Setting

Guide on setting operation parameters for the XBF-AD04A module using XG5000 software via I/O parameters.

2.10 Special Module Monitoring Functions

Explanation of how to use the special module monitoring features for testing and monitoring the XBF-AD04A module.

2.11 Register U devices

Procedure for registering variables and comments for the XBF-AD04A module using the I/O parameter.

2.12 Configuration and Function of Internal Memory

Details the internal memory configuration and I/O area for A/D converted data in the XBF-AD04A module.

Chapter 3 Analog Output Module

3.1 Setting Sequence before Operation

Step-by-step guide for the initial setup and operation of the analog output module (XBF-DV04A, XBF-DC04A, XBF-DC04B).

3.2 Specification

General specifications for the analog output module, covering environmental conditions and performance metrics.

3.3 Designations and Functions

Identification and description of the parts and their functions on the analog output modules.

3.4 Characteristic of I/O Conversion

Explanation of the I/O conversion characteristics for analog output modules, showing the relationship between digital input and analog output.

3.5 Characteristic of Input/Output

Details the input/output characteristics for voltage and current outputs, with conversion tables provided.

3.6 Accuracy

Information on the accuracy of the analog output module, specifying the range at ambient temperatures.

3.7 Functions of Analog Output Module

Overview of the functions of the analog output module, including channel control, range settings, and output status.

3.8 Wiring

Precautions and examples for correctly wiring analog output modules to external devices.

3.9 Operation Parameter Setting

Guide on setting operation parameters for the analog output module using XG5000 software via I/O parameters.

3.10 Special Module Monitoring Function

Explanation of how to use the special module monitoring features for testing and monitoring the analog output module.

3.11 Register U devices (special module variable)

Procedure for registering variables and comments for the analog output module using I/O parameters.

3.12 Internal memory

Details the internal memory configuration and I/O area for analog output data.

Chapter 4 RTD Input Module

4.1 Setting Sequence before Operation

Step-by-step guide for the initial setup and operation of the RTD input module (XBF-RD04A, XBF-RD01A).

4.2 Specification

General specifications for the RTD input module, covering environmental conditions and performance metrics.

4.3 Part Names and Functions

Identification and description of the parts and their functions on the XBF-RD04A/XBF-RD01A RTD input module.

4.4 Temperature Conversion Characteristic

Explanation of the temperature conversion characteristics for RTD sensors, including linearization processes.

4.6 Accuracy

Information on the accuracy of the RTD module, specifying values based on ambient temperature.

4.8 Scaling Function

Description of the scaling function used to scale and output ranges specified by the user.

4.9 Disconnection Detection Function

Explanation of the function to detect and display disconnection of the RTD temperature sensor.

4.10 Wiring

Guidelines and examples for wiring RTD sensors to the module, including precautions for different sensor types.

4.12 Operation Parameter Setting

Guide on setting operation parameters for the RTD module using XG5000 software via I/O parameters.

4.13 Special Module Monitoring

Explanation of how to use the special module monitoring features for testing and monitoring the RTD input module.

4.14 Register U devices (Special module variable)

Procedure for registering variables and comments for the RTD module using I/O parameters.

4.15 Configuration and Function of Internal Memory

Details the internal memory configuration and data I/O area for RTD input modules.

4.16 Example Program

Example program demonstrating how to specify operation conditions and read temperature/disconnection information.

4.17 Trouble Shooting

Methods for identifying and resolving troubleshooting issues related to RTD input modules.

Chapter 5 Thermocouple Input Module

5.2 Specification

Detailed specifications for the thermocouple input module, including general, performance, and common specifications.

5.2.3 Name of part and function

Identification and description of the parts and their functions on the thermocouple input module.

5.2.4 Characteristic of thermocouple temperature conversion

Explanation of the thermocouple temperature conversion characteristics, including graphs for different thermocouple types.

5.2.6 Accuracy / Resolution

Accuracy and resolution specifications for thermocouple input modules based on ambient temperature.

5.3 Function

Overview of the functions of the thermocouple input module, including disconnection detection.

5.4 Installation and Wiring

Guidelines and precautions for installing and wiring thermocouple input modules, covering environmental and wiring aspects.

5.5 Operation Setting and Monitor

Procedure for setting operation parameters and monitoring the thermocouple input module using XG5000.

5.5.2 Special module monitoring function

Explanation of how to use the special module monitoring features for testing and monitoring the thermocouple input module.

5.5.3 Register U devices (Special module variable)

Procedure for registering variables and comments for the thermocouple input module using I/O parameters.

5.6 Configuration and Function of Internal Memory

Details the internal memory configuration and data I/O area for thermocouple input modules.

Chapter 6 Analog I/O Module

6.1 Pre-operation Setting Procedure

Step-by-step guide for the initial setup and operation of the XBF-AH04A analog I/O module.

6.2 Specification

General specifications for the analog I/O module, covering environmental conditions and performance metrics.

6.3 Major Components

Identification and description of the major components of the XBF-AH04A analog I/O module.

6.4 Conversion Characteristics by I/O Range

Explanation of the I/O conversion characteristics for analog I/O modules, showing data conversion based on input/output ranges.

6.5 Precision

Information on the precision of the digital output and analog input for the XBF-AH04A module.

6.6 Functions of Analog I/O Module

Overview of the functions of the XBF-AH04A analog I/O module, including channel control, I/O settings, and conversion methods.

6.7 Wiring

Guidelines and examples for wiring analog I/O modules, including precautions and connection diagrams.

6.8 Operation Parameter Setting

Guide on setting operation parameters for the analog I/O module using XG5000 software via I/O parameters.

Chapter 7 Analog Input Module (XBF-AD08A)

Chapter 8 Analog Input Option Board

Chapter 9 Analog Output Option Board

Chapter 10 Analog I/O Option Board

Chapter 11 RTD Input Option Board

Chapter 12 Thermocouple Input Option Module

Chapter 13 Analog Input Module

Chapter 14 Analog Output Module

Chapter 15 PID Function (Built-in function)

Related product manuals