Right choice for ultimate yield
LSIS strives to maximize customers' profit in gratitude of choosing us for your partner.
Programmable Logic Controller
XGB Cnet I/F
Users Manual
Read this manual carefully before
installing,
wiring, operating, servicing
or inspecting this equipment.
Keep this manual within easy reach
for quick reference.
XGT Series
http://www.lsis.com
Main Unit
Built
-in Cnet
S TYPE
E TYPE
S TYPE
SU TYPE
H TYPE
Cnet I/F
module
-C21A
XBM
XBC
/XEC
XBC
/XEC
XBC
/XEC
XBC
/XEC

Table of Contents

Questions and Answers

  • A
    Amanda AndersenAug 8, 2025
    How to fix P2P setting error warning in LSIS Controller when connecting to XG5000?
    • G
      Gina JenkinsAug 9, 2025
      To resolve a P2P setting error warning during XG5000 connection, follow these steps: 1. In the Enable Link menu of XG5000, verify the P2P setting number and remove any incorrectly selected P2P numbers. 2. After disconnecting XG-PD, reconnect XG5000 and check again.
  • M
    Meagan YangAug 14, 2025
    Why Tx/Rx LED of Cnet I/F doesn’t flicker after completing tough communication setting on LSIS Controller?
    • S
      Sandra JacksonAug 15, 2025
      If tough communication setting is completed, Tx/Rx LED of Cnet I/F doesn’t flicker, consider the following possible causes: * If the CPU is in stop mode, connect XG5000 and check the CPU mode. If it's in stop mode, change it to RUN. * If there's a mismatch in communication standard parameters between the client and server, connect XG-PD and go to [File] – [Open from PLC]. Check the standard settings of the module acting as the client and server. * If there's an Enable Link setting error, enable the correct P2P link after executing the P2P parameter.
  • J
    Joseph FryAug 20, 2025
    Why is communication not normal or not executed repeatedly on LSIS XBL-C21A?
    • C
      Courtney BennettAug 20, 2025
      If, in a multi-drop configuration, more than one server sends a frame, execute 1:1 communication with the server to verify proper operation. Additionally, implement an interlock to prevent servers from sending frames simultaneously. If there is a connection error in the wiring communication line, change the cable or check the cable connection. If using RS-485 (Half duplex) and the timing of the TRX signal is not coincident, increase the delay time of both the client and server. If transmission or reception is incomplete and the next process is requested, use handshake in program thoroughly.
  • J
    Joyce PetersonAug 27, 2025
    What to do if frame monitor misses response frame after setting P2P parameter in LSIS Controller?
    • J
      Julie WalkerAug 27, 2025
      If the frame monitor misses the response frame after setting diverse P2P parameters in the P2P block, consider these potential causes: * If the P2P conditional flag is faster than the communication time: 1. Adjust the P2P conditional flag considering the communication time. 2. Note that communication time = transmission time + reception time. Transmission time = conditional flag + CPU Scan Time + reaction time of communication module + data transmission time. Reception time = CPU Scan Time + reaction time of communication module + data transmission time. * If the response time of the partner is slow: Increase the Delay time in the standard settings of XG-PD.
  • A
    Amy FernandezSep 2, 2025
    Why am I unable to analyze TRX frame on LSIS XBL-C21A?
    • J
      Jennifer FlemingSep 2, 2025
      To resolve the issue of being unable to analyze the TRX frame, consider the following potential causes: * If more than one server sends a frame, first, execute 1:1 communication with the server to ensure it functions correctly. Second, implement an interlock to prevent servers from sending frames simultaneously. * If the parity bit setting is not coincident, ensure that the parity bit settings are the same for all devices. * If the stop bit setting is not coincident, ensure that the stop bit settings are the same for all devices. * If the communication speed setting is not coincident, ensure that the communication speed settings are the same for all devices. * In the case of a multi-drop configuration, if terminal resistance is not installed, install terminal resistance.

Summary

Programmable Logic Controller XGB Cnet I;F

Safety Instructions

Read safety instructions thoroughly before using the product to ensure safety and effective operation.

Safety Instruction

Safety Instructions when designing

Guidelines for safe system design, including protection circuits and error handling.

Safety Instructions when wiring

Precautions for safe electrical wiring and connections to prevent hazards and ensure proper operation.

Safety Instructions for test-operation or repair

Safety measures to be taken during testing, operation, and repair of the equipment.

Chapter 1 General

Chapter 2 Specification

2.2 Performance Specification

Details the performance specifications for the XGB built-in Cnet and extension Cnet communication modules.

Chapter 3 System Configuration

3.2 Available System Configuration

Illustrates various system configuration examples for XGB PLC communication, including 1:1 connections.

Chapter 4 Basic Setting

4.2 PLC Type Setting and How to Register Communication Module

Explains how to set PLC type and register communication modules using XG-PD in both offline and online modes.

4.3 How to Set Basic Parameter

Describes the communication functions of Cnet I/F modules, including server mode, P2P service, and loader service.

Chapter 5 Remote Connection

5.1 Remote Connection

Explains how to establish remote connections for controlling XGB PLCs using Cnet I/F modules via modem or other communication methods.

Chapter 6 Server function and P2 P service

6.1 Server Modbus Service

Details the built-in server service in Cnet I/F modules, supporting XGT and Modbus protocols for data read/write.

6.2 P2 P Service

Explains P2P service, allowing Cnet I/F modules to act as clients for communication and data exchange.

Chapter 7 XGT Dedicated Protocol

7.1 XGT Dedicated Protocol

Describes the XGT series dedicated protocol for communication between LSIS products, covering its functions and configuration.

Chapter 8 LS Bus Protocol

Chapter 9 Modbus Communication

9.2 Modbus Protocol

Explains the two communication modes of Modbus (ASCII and RTU) and the structure of the Modbus protocol.

9.4 Modbus Protocol

Covers various Modbus function codes for reading and writing data, including frame details and examples.

Chapter 10 Example Program

10.1 Setting of Cnet I;F module in the XG-PD

Provides step-by-step examples for setting Cnet I/F modules in XG-PD for server and P2P client operations.

Chapter 11 Diagnosis

11.2 Trouble Shooting by Error

Provides guidance on troubleshooting common errors encountered during P2P parameter setting, communication, and frame monitoring.

Chapter 12 Installation and Wiring

12.1 Safety Instruction

Highlights critical safety precautions and dangers related to PLC installation, wiring, and operation.

12.1.1 Fail safe circuit

Explains the design and implementation of fail-safe circuits for PLC systems to ensure safe operation in case of errors.

Chapter 13 Maintenance

LSIS XBL-C21A Specifications

General IconGeneral
BrandLSIS
ModelXBL-C21A
CategoryController
LanguageEnglish