LSIS XBL-C41A - User Manual

LSIS XBL-C41A
194 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Right choice for ultimate yield
LSIS strives to maximize customers' profit in gratitude of choosing us for your partner.
Programmable Logic Controller
XGB Cnet I/F
Users Manual
Read this manual carefully before
installing,
wiring, operating, servicing
or inspecting this equipment.
Keep this manual within easy reach
for quick reference.
XGT Series
http://www.lsis.com
Main Unit
Built
-in Cnet
S TYPE
E TYPE
S TYPE
SU TYPE
H TYPE
Cnet I/F
module
-C21A
XBM
XBC
/XEC
XBC
/XEC
XBC
/XEC
XBC
/XEC

Table of Contents

Questions and Answers

  • K
    Krista CamposAug 8, 2025
    How to fix P2P setting error warning in LSIS XBL-C41A when connecting to XG5000?
    • L
      Laura AliAug 9, 2025
      To resolve a P2P setting error warning during XG5000 connection, follow these steps: 1. In the Enable Link menu of XG5000, verify the P2P setting number and remove any incorrectly selected P2P numbers. 2. After disconnecting XG-PD, reconnect XG5000 and check again.
  • G
    ghendersonAug 15, 2025
    Why Tx/Rx LED of Cnet I/F doesn’t flicker after completing tough communication setting on LSIS Controller?
    • T
      twilliamsAug 15, 2025
      If tough communication setting is completed, Tx/Rx LED of Cnet I/F doesn’t flicker, consider the following possible causes: * If the CPU is in stop mode, connect XG5000 and check the CPU mode. If it's in stop mode, change it to RUN. * If there's a mismatch in communication standard parameters between the client and server, connect XG-PD and go to [File] – [Open from PLC]. Check the standard settings of the module acting as the client and server. * If there's an Enable Link setting error, enable the correct P2P link after executing the P2P parameter.
  • C
    Christina OwensAug 21, 2025
    Why is communication not normal or not executed repeatedly on LSIS XBL-C41A Controller?
    • S
      Samantha QuinnAug 21, 2025
      If, in a multi-drop configuration, more than one server sends a frame, execute 1:1 communication with the server to verify proper operation. Additionally, implement an interlock to prevent servers from sending frames simultaneously. If there is a connection error in the wiring communication line, change the cable or check the cable connection. If using RS-485 (Half duplex) and the timing of the TRX signal is not coincident, increase the delay time of both the client and server. If transmission or reception is incomplete and the next process is requested, use handshake in program thoroughly.
  • B
    Brandy JohnsonAug 27, 2025
    What to do if frame monitor misses response frame after setting P2P parameter in LSIS XBL-C41A?
    • S
      Sharon SchmidtAug 27, 2025
      If the frame monitor misses the response frame after setting diverse P2P parameters in the P2P block, consider these potential causes: * If the P2P conditional flag is faster than the communication time: 1. Adjust the P2P conditional flag considering the communication time. 2. Note that communication time = transmission time + reception time. Transmission time = conditional flag + CPU Scan Time + reaction time of communication module + data transmission time. Reception time = CPU Scan Time + reaction time of communication module + data transmission time. * If the response time of the partner is slow: Increase the Delay time in the standard settings of XG-PD.
  • S
    Stacy WhiteheadSep 2, 2025
    Why am I unable to analyze TRX frame on LSIS XBL-C41A Controller?
    • K
      Kathryn JenkinsSep 2, 2025
      To resolve the issue of being unable to analyze the TRX frame, consider the following potential causes: * If more than one server sends a frame, first, execute 1:1 communication with the server to ensure it functions correctly. Second, implement an interlock to prevent servers from sending frames simultaneously. * If the parity bit setting is not coincident, ensure that the parity bit settings are the same for all devices. * If the stop bit setting is not coincident, ensure that the stop bit settings are the same for all devices. * If the communication speed setting is not coincident, ensure that the communication speed settings are the same for all devices. * In the case of a multi-drop configuration, if terminal resistance is not installed, install terminal resistance.

Summary

Chapter 3 System Configuration

Chapter 4 Basic Setting

4.1 Product Setup Sequence

Outlines the step-by-step procedure for installing and setting up the Cnet I/F module.

4.3 Basic Parameter Settings

Explains how to set communication parameters like speed, data bit, and parity.

Chapter 5 Remote Connection

5.1.2 XG5000 Remote Connection

Details remote connection methods using XG5000, including modem connections.

Chapter 6 Server and P2 P Service

6.1 Server Modbus Service

Describes the built-in server function supporting XGT and Modbus protocols.

6.2 P2 P Service Operations

Explains P2P service for client operations, including parameter setup and block configuration.

Chapter 7 XGT Dedicated Protocol

7.1 XGT Dedicated Protocol

Details the XGT series dedicated communication protocol and its functions.

Chapter 10 Example Programs

10.1 Cnet I;F Module Setup in XG-PD

Provides step-by-step guides for setting Cnet I/F modules as server or client.

10.2 Dedicated Communication Example

Illustrates dedicated communication setup between XGT server and client.

10.3 Modbus Communication Example

Demonstrates Modbus RTU server and client configuration examples.

Chapter 11 Diagnosis

11.1 XG-PD Diagnosis Functions

Explains how to use XG-PD for system and network diagnosis.

11.2 Troubleshooting Common Errors

Provides troubleshooting steps for common communication errors.

Chapter 12 Installation and Wiring

12.1 Safety Instructions

Provides critical safety instructions for PLC installation and wiring.

12.5 Communication Interface Connections

Explains connection methods for RS-232C, RS-422, and RS-485 interfaces.

Chapter 13 Maintenance

Appendix 3 Communication Error Codes

LSIS XBL-C41A Specifications