EasyManua.ls Logo

LSIS XBM-DN32S - User Manual

LSIS XBM-DN32S
315 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Right choice for ultimate yield
LSIS strives to maximize customers' profit in gratitude of choosing us for your partner.
Programmable Logic Controller
XGB Built-in Positioning
Users Manual
Read this manual carefully before
installing,
wiring, operating, servicing
or inspecting this equipment.
Keep this manual within easy reach
for quick reference.
XEC-DN20SU
XEC-DN30SU
XEC-DN40SU
XEC-DN60SU
XEC-DP20SU
XEC-DP30SU
XEC-DP40SU
XEC-DP60SU
XEC-DN32H
XEC-DN64H
XEC-DP32H
XEC-DP64H
XGT Series
http://eng.lsis.biz
XBM-DN16S
XBM-DN32S
XBC-DN20S(U)
XBC-DN30S(U)
XBC-DN40SU
XBC-DN60SU
XBC-DP20SU
XBC-DP30SU
XBC-DP40SU
XBC-DP60SU
XBC-DN32H(/DC)
XBC-DN64H(/DC)

Table of Contents

Questions and Answers

  • K
    Kenneth ElliottAug 15, 2025
    What to do if PWR LED is off on LSIS XBM-DN32S?
    • B
      Bryan FuentesAug 15, 2025
      If the PWR LED is off on your LSIS Controller, first verify that the rated voltage is being supplied to the PLC. If the voltage supply is normal, it may indicate a hardware problem. Contact an A/S office or customer center for assistance.
  • M
    Matthew MartinezAug 18, 2025
    What to do if PWR LED is flashing on LSIS Controller?
    • J
      John Moss MDAug 18, 2025
      If the PWR LED is flashing on your LSIS Controller, check the voltage and current of the power supply. If the problem persists, remove the input and output lines, re-supply power, and check again. If the problem continues, contact the A/S office or customer center.
  • K
    Kendra DavisAug 21, 2025
    How to fix ERR LED flashing quickly on LSIS XBM-DN32S?
    • L
      Linda ClarkAug 21, 2025
      When the ERR LED is flashing quickly on the LSIS Controller, it indicates a serious problem that prevents operation. Access the XGB with XG5000, go to ‘Online’ -> ‘PLC error/warning’, then check the error and warning messages, and resolve the underlying cause.
  • M
    Mark EspinozaAug 25, 2025
    Why is RUN LED off on LSIS XBM-DN32S Controller?
    • K
      Katie PearsonAug 25, 2025
      If the RUN LED is off on your LSIS Controller, it means that the program has stopped running. Check the ERR LED to determine if the program stopped due to an error or because the operation mode is set to STOP.
  • E
    erica33Aug 27, 2025
    What to do if Positioning Output LED is off on LSIS XBM-DN32S?
    • Y
      ypriceAug 27, 2025
      If the Positioning Output LED is off on the LSIS Controller, it indicates that the pulse is not being output normally, or the positioning operation has finished normally. If the operation finished normally, start the next operation instruction. If there is an error, check the positioning error code and resolve the cause.
  • Z
    zhallAug 30, 2025
    What does it mean when ERR LED is on LSIS XBM-DN32S Controller?
    • K
      Kevin ClarkAug 30, 2025
      If the ERR LED is on for the LSIS Controller, there is a problem with the PLC hardware. Contact an A/S office or customer center for assistance.
  • B
    blackdannySep 2, 2025
    Why is Positioning Output LED fast flashing on LSIS XBM-DN32S?
    • M
      Matthew RossSep 2, 2025
      If the Positioning Output LED is flashing quickly, it means the pulse is being normally output by the positioning function. Check the lines of the XGB and motor driver to ensure there are no issues.
  • O
    olivershellySep 5, 2025
    What does it mean when PWR LED is on LSIS XBM-DN32S?
    • S
      smithbrandonSep 5, 2025
      If the PWR LED is on for the LSIS Controller, the power supply is normal. Check whether there is another cause for the issue you are experiencing.
  • G
    Gary CooperSep 8, 2025
    What does Direction Output LED On (HIGH Active) mean on LSIS XBM-DN32S Controller?
    • M
      Mrs. Nancy ReyesSep 8, 2025
      If the Direction Output LED is on (HIGH Active) for the LSIS controller, it means that direction signals are being output in the reverse direction, or the positioning operation has finished normally. Start the next operation instruction. If there is an error that makes positioning operation impossible, check the positioning error code and remove the cause.
  • T
    tylergrahamSep 12, 2025
    What does it mean when RUN LED is on LSIS XBM-DN32S?
    • D
      Donna FaulknerSep 12, 2025
      If the RUN LED is on for the LSIS Controller, it means the program is operating normally. Check whether there is another cause for any issues you might be experiencing.

LSIS XBM-DN32S Specifications

General IconGeneral
Digital Inputs16
Input Voltage24 VDC
Digital Outputs16
Output TypeTransistor
Programming SoftwareXG5000
Protection ClassIP20
Communication InterfaceRS-485
Operating Temperature0 to 55°C
Humidity5 to 95% RH (non-condensing)