Chapter 2 specification
2-1
Chapter 2 Specification
2.1 General Specification
General specification of XGB PLC is as follows.
No. Item Specification Related specifications
1
Operating
temp.
0℃∼+55
2 Storage temp. -25℃∼+70
3
Operating
humidity
595%RH, no dew allowed
4
Storage
humidity
595%RH, no dew allowed
5
Vibration
proof
For discontinuous vibration
Frequency Acceleration Amplitude Number
IEC 61131-2
10f< 57 - 0.075mm
Each 10 times
in X,Y,Z
directions
57f150 9.8 -
For continuous vibration
Frequency Acceleration Amplitude
10f< 57 - 0.035mm
57f150 4.9(0.5G) -
6 Impact proof
* Max. impact acceleration: 147(15G)
* Authorized time: 11
* Pulse wave : Sign half-wave pulse
(
Each 3 times in X
,
Y
,
Zdirections
)
IEC 61131-2
7 Noise proof
Square wave impulse noise AC:±1,500V, DC: 500 V
Test spec of LS
Industrial Systems
Static electric discharging
Voltage: 4 kV
(contact discharging),
8 kV (air discharging)
IEC 61131-2,
IEC 61000-4-2
Radiation electromagnetic 80 ~ 1,000MHz, 10 V/m
IEC 61131-2,
IEC 61000-4-3
Fast
Transient
/burst
noise
Class
Power
module
Digital/
Analog I/O
communication interface
IEC 61131-2,
IEC 61000-4-4
Voltage 2kV 1kV
8
Ambient
conditions
No corrosive gas or dust
9
Operating
height
2000m or less
10 Pollution level 2 or less
11 Cooling type Natural air cooling