EasyManua.ls Logo

Lucent Technologies DACS II - Remote Loopback Process

Lucent Technologies DACS II
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 2.0 April 2000
1-5
365-353-255
DACS II Operation and Maintenance Manual
Release 8.2.6 Features
Remote Loopback Feature (Continued)
Remote Loopback
Process
The following process, illustrated in Figure 1-1, is used to set up the Remote
Loopback test:
1. The local multiplexer activates the Remote Loopback signal.
2. The remote multiplexer detects the loopback signal.
3. The remote multiplexer activates the loopback.
4. A test signal is sent through the local multiplexer and over the specified
DS1/E1 tributary. This signal will be sent back towards the local multiplexer.
5. The looped back test signal is received by the local multiplexer and a
comparison is made between the sent and received signals to determine
the condition of each multiplexer and facility between them.
Figure 1-1. Remote Loopback Process
MUX
DEMUX
MUX
DEMUX
Downstream
U
p
stream
DS3 Facilit
y
E-1 or DS1
DSX
1 Activate Loo
p
back Si
g
nal
2 Detect Loo
p
back Si
g
nal
3 Activate Loo
p
back
4 Send Test Si
g
nal
MUX = Multi
p
lexer
DEMUX = Demulti
p
lexer
KCR8 HMXR
Remote Multi
lexer
DSX = DS1 or E-1 tributar
y
of H
y
brid DS3 si
g
nal
5 Receive Test Si
g
nal
//
IFTU
NPC
Local Multi
p
lexer (DACS II)
.
.
E-1
or
DS1
.
DSX
//
.
AIS