Acceptance: NTP-004 363-205-401
Page 2 of 2 Issue 7, March 1997
DO ITEMS BELOW IN ORDER LISTED FOR DETAILS, GO TO
5. Check AC power, grounding, drop wire protector panel, and fiber
termination.
DLP-503A. For single DT site.
DLP-504B. For common AC powered DT site (for example low profile
pedestal).
6. Close and secure 900A1 DT (if not performing turnup procedures
at this time).
DLP-5057. Open the low profile pedestal housing the 900A2 or 900A3 DTs
and perform an overall visual inspection of the enclosure, DC
power interface, and 900A2 or 900A3 DTs for physical damage
and proper mounting. Check DC power interface and 900A2 or
900A3 DT for proper grounding, copper termination, and fiber ter-
mination.
8. Close and secure 900A2 or 900A3 DT and pedestal (if not per-
forming turnup procedures at this time).