Operating Manual Compact Weather Station
22 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Figure 5: Installation
Sketch
7.3.4 Sensors with Global Radiation Measurement
Installation on top of the pole
Shadow free location, if possible 360° free view to the horizon at the height of the
pyranometer
Distance to shadow casting objects (trees, buildings) at least 10 times of the object height
relative to the sensor.
7.3.5 Installation Sketch
Example WS600-UMB:
Road
carriageway
min. 10 m
min. 4.5 m
WS600-UMB
Mast
min. 10 m
Tree, bush
etc.