EasyManua.ls Logo

Lufft WS200-UMB - Technical Data; Measuring Range; Accuracy; Drawings

Lufft WS200-UMB
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual Compact Weather Station
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 35
13 Technical Data
Power supply: 24VDC +/- 10%
12VDC with restrictions (see page 23)
Current consumption and power input - sensor:
24VDC standard
1
12VDC energy save mode
2
WS200-UMB
ca. 50 mA / 1.2VA
ca. 16.5mA / 0.2VA
WS300-UMB, WS301-UMB
ca. 145 mA / 3.5VA
ca. 16.5mA / 0.2VA
WS400-UMB
ca. 170 mA / 4.1VA
ca. 17.5mA / 0.2VA
WS500-UMB, WS501-UMB
ca. 150 mA / 3.6VA
ca. 16.5mA / 0.2VA
WS600-UMB
ca. 175mA / 4,2VA
ca. 17.5mA / 0.2VA
Current consumption and power input - heating:
WS200-UMB 833 mA / 20VA at 24VDC
WS400-UMB 833 mA / 20VA at 24VDC
WS500-UMB, WS501-UMB 833 mA / 20VA at 24VDC
WS600-UMB 1.7 A / 40VA at 24VDC
Dimensions including mounting bracket:
WS200-UMB Ø 150mm, height 194mm
WS300-UMB Ø 150mm, height 223mm
WS301-UMB Ø 150mm, height 268mm
WS400-UMB Ø 150mm, height 279mm
WS500-UMB Ø 150mm, height 287mm
WS501-UMB Ø 150mm, height 332mm
WS600-UMB Ø 150mm, height 343mm
Weight including mounting bracket, excluding connection cable:
WS200-UMB ca. 0.8 kg
WS300-UMB ca. 1.0 kg
WS400-UMB, WS301-UMB ca. 1.3 kg
WS500-UMB ca. 1.2 kg
WS600-UMB, WS501-UMB ca. 1.5 kg
Fastening: Stainless steel mast bracket for Ø 60 - 76mm
Protection class: III (SELV)
Protection type: IP64
Storage Conditions
Permissible storage temperature: -50°C ... +70°C
Permissible relative humidity: 0 ... 100% RH
Operating Conditions
Permissible operating temperature: -50°C ... +60°C
Permissible relative humidity: 0 ... 100% RH
Permissible altitude above sea level: N/A
RS485 interface, 2 wire, half-duplex
Data bits: 8 (SDI-12 mode: 7)
Stop bit: 1
Parity: No (SDI-12 mode: even, Modbus mode none or
even)
Tri-state: 2 bits after stop bit edge
Adjustable baud rates: 1200, 2400, 4800, 9600, 14400, 19200
3
, 28800, 57600
(In SDI-12 mode, the interface is changed to meet the requirements of the standard.)
Housing: Plastic (PC)
1
Factory setting; recommended setting
2
This setting must be set in the device configuration. For maximum energy saving, a device with version 025 or
higher is required (last position of the serial number).
3
Factory setting; baud rate for operation with ISOCON-UMB and firmware update.

Table of Contents

Related product manuals