Operating Instructions Compact Weather Station
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 87
Sensor status codes:
Sensor status
Code
OK
0
UNGLTG_KANAL
1
E2_CAL_ERROR
E2_CRC_KAL_ERR
FLASH_CRC_ERR
FLASH_WRITE_ERR
FLASH_FLOAT_ERR
2
MEAS_ERROR
3
MEAS_UNABLE
4
INIT_ERROR
5
VALUE_OVERFLOW
CHANNEL_OVERRANGE
6
VALUE_UNDERFLOW
CHANNEL_UNDERRANGE
7
BUSY
8
other sensorstatus
9
Example (WS600-UMB, SDI-12 Address ‘0’, no error):
0V!
00007<CR><LF>
0D0!
0+0000+000000+00000<CR><LF>
0D1!
0+73.0+65.3<CR><LF>
Example (WS600-UMB, SDI-12 Address ‘0’, compass failure):
0V!
00005<CR><LF>
0D0!
0+0000+000000+000030<CR><LF>
0D1!
0+73.0+65.3<CR><LF>