Luminell Norway AS Doc. Nr.: D0011 RLX CxZ1.21 User Manual v1.5
Page 3 of 9
4 MARKING
Identification according to IECEx Scheme:
Identification according to 2014/34/EU (ATEX):
Certificate number: IECEx CML16.0048
II 2G Ex eb mb IIC T3,T4,T5,T6 Gb
II 2D Ex tb IIIC T200,T135,T100,T85 Db
Ta: -55°C ≤ Ta ≤ 40,50,55°C
Certificate number: CML16ATEX3108
Ex eb mb IIC T3,T4,T5,T6 Gb
Ex tb IIIC T200,T135,T100,T85 Db
Ta: -55°C ≤ Ta ≤ 40,50,55°C
5 CERTIFICATE
Online link to certificate: www.luminell.com/downloads
6 CONTENT
Box content:
Required tools:
Fully assembled
RLX CxZ1.21 LED floodlight
User Manual
Recyclable cardboard
Allan Key 5mm
Flat screwdriver (2mm slot)
2x 17mm combination spanners
22,24 and/or 30mm combination spanner
Wire stripper
Additional cable glands (optional)
7 SPECIFICATIONS
Voltage Input
AC: 100-277 VAC 50-60Hz
DC: 100-300 VDC
Current
160W: 0.8 A @ 230 VAC
Power factor
cos <0.95
Consumption
40, 80, 120 or 160 W
Ambient Temperature
-55°C ≤ Ta ≤ 40,50,55°C
IP rating
IP66/67
Weight
9,7kg (21,4 lbs.)
Cable glands
2x M25 Cable glands
2x M20 Blind caps
Light beam angle, temperature class and power variation see “Type overview”
7.1 CABLE GLANDS
Make sure to replace unused cable glands with blind caps M20 or M25. Use 55°C to >80°C rated EX
approved cable glands if the blind caps is exchanged. Lower ambient temperature range will be limited to
the temperature rating of the used cable gland. Warranty will be voided if replaced cable glands / blind
caps are not UV and weather resistant. In addition, it is the installers responsibility to ensure that the cable
and cable glands are appropriate for each other and properly sealed. For EMC compliance to MIL-STD461F
Navy Mobil & Army, overall screening must be terminated 360° in the cable gland.