0817V2.1CT
Lunos Operation Manual
Knowing how to operate the Lunos e2 and eGO HRV systems will help you get the most out of
balanced, decentralized heat recovery ventilation. Your Lunos should already have been set up to be
operating continuously and providing healthy indoor air quality to your living spaces. However, you
may want to change the flow rates at night or in summer depending on your individual preferences.
This guide will help you determine the best ventilation strategy for your needs.
How Lunos works an introduction
The basic Lunos unit is a through wall fan, with a ceramic regenerative heat exchanger behind it. But
the fan doesn't become a heat recovery ventilation
system
until two fan units are combined in pairs.
Each Lunos system provides heat recovery ventilation by synchronizing the direction and speed of air
flow through the ceramic cores. By reversing the air flow on regular intervals, the
ceramic cores capture and release heat to condition the interior space at optimal efficiency - while
maintaining balanced ventilation. Depending on your Lunos model, the reversal interval will be either
55 or 70 seconds.
With the Lunos e², fan pairs will be inside two different tubes that are generally on opposite ends of
your space. (For the Lunos eGO, both fans are in the same tube.) A maximum of 4 Lunos e2 fans can
be connected to one controller (a double rocker switch or rotary dial switch aka Miceli). Therefore, if
your dwelling unit has more than 4 fans, you will have more than one controller.

Other manuals for Lunos eGO

Question and Answer IconNeed help?

Do you have a question about the Lunos eGO and is the answer not in the manual?

Summary

Understanding Lunos Operation

How Lunos Works: An Introduction

Explains the basic Lunos unit, ceramic heat exchanger, and paired fan operation for heat recovery ventilation.

Operating Your Lunos System

Lunos e² Switch Positions

Details the four switch positions (OFF, LOW, MEDIUM, HIGH) and their corresponding CFM settings for the Lunos e² system.

Lunos System Modes

Continuous Operation Benefits

Highlights the advantages of continuous 24/7 operation for optimal indoor air quality and system efficiency.

Turning the System Off

Provides specific steps for temporarily turning off the Lunos system, including cover adjustments.

Summer Ventilation Mode

Describes the mode for passive cooling, running fans in one direction for 60 minutes to flush air.

Specific Operating Conditions

Setting Summer Ventilation Mode

Instructions on how to activate and return from Summer Ventilation mode using the rocker switches.

Extreme Cold Weather Operation

Recommendations for operating at LOW (10 CFM) and managing humidity below -10F to prevent frost issues.

Filter Maintenance and Indicator

Details the filter maintenance schedule, indicator light, and cleaning/replacement advice.

General Maintenance & Support

Annual Fan Unit Cleaning

Guidance on performing annual general maintenance, including cleaning fan units and heat exchangers.

Installation and Further Assistance

Points to installation instructions and contact information for additional support or questions.

Lunos eGO Specifications

General IconGeneral
Heat Recovery EfficiencyUp to 90%
TypeDecentralized Ventilation System
ControlManual or automatic control
InstallationWall-mounted
MaterialPlastic

Related product manuals