CDA3000 Operation Manual
4-19
4 Commissioning
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
4.9 Parameter list
(selection)
Any parameters can be
inserted into this
subject area using the
D
RIVEMANAGER (V3.0 or
higher). The number is
limited to 14. *
In the factory setting
the parameters listed
here are inserted.
* For more information
refer to the D
RIVEMANAGER
M
ANUAL.
Name Unit Function
Factory
setting
Your
setting
Subject area User-defined_11UA
01-MODE - User level of KP200 2
150-SAVE - Save setting in device READY
152 -ASTER - Preset terminal assignment DRV_1
180 -FISA0 - Function selector of ISA00 off
181 -FISA1 - Function selector of ISA01 off
242 -FOS02 - Function selector of OSD02 off
270-FFIX1 Hz
Fixed frequency characteristic data
set CDS1
20
301 -FMIN1 Hz CDS1: Minimum frequency 0
303 -FMAX1 Hz CDS1: Maximum frequency 50
330-MOPTC - Type of PTC evaluation off
590 -ACCR1 Hz/s CDS1: Acceleration ramp 20
592 -DECR1 Hz/s CDS1: Braking ramp 20
594 -STPR1 Hz/s CDS1: Stop ramp 20
95-ERR1 h Last error -
Subject area Initial commissioning _15FC
150-SAVE - Back-up device setup READY
152 -ASTER - Preset terminal assignment DRV_1
Subject area Fixed frequencies_27FF
270-FFIX1 Hz Fixed frequency 20
Subject area Frequency limits_30OL
301 -FMIN1 Hz CDS1: Minimum frequency 0
303 -FMAX1 Hz CDS1: Maximum frequency 50
Subject area Motor protection _33MO
330-MOPTC - Type of motor PTC evaluation OFF
Subject area Driving profile generator _59DP
590 -ACCR1 Hz/s CDS1: Acceleration ramp 20
592 -DECR1 Hz/s CDS1: Deceleration ramp 20
594 -STPR1 Hz/s CDS1: Stop ramp 20
Subject area Encoder evaluation _79EN
790-ECLNC
Pulses
per rev
Lines per revolution of encoder 1024