Application Note #480
10 www.lutron.com
Programming Option 1: Preset Light Level (continued)
3. To Save the desired light intensity, Press the Tap button. This will exit out of the Programming Option 1: Preset Light
Level and return to APM main menu.
The default light setting has now been redefined. A single tap of the Tap button (when in Normal Operation, not APM)
will now always return the dimmer to this selected light setting until preset is deactivated or reset. A double tap will
always bring the lights to full intensity.
Selecting "Unlocked Preset"
1. To deactivate a Locked Preset setting so that the dimmer will turn ON to the light level that it was last set to
while in Normal Operation, the Unlocked Preset must be activated.
While in Programming Option 1: Preset Light Level, Press the Lower button until the bottom Indicator Light is
quickly flashing (IL1). Release the Lower button and Press and Hold the Lower button again for approximately 3
seconds or until all Indicator Lights turn OFF.
Note: The light will remain at its minimum output when you perform this action.
2. To Save the Unlocked Preset, Press the Tap button. This will exit out of the Programming Option 1: Preset Light
Level and return to APM main menu.
Note:
• If there is no button activity for 1 minute, the dimmer will automatically exit APM, however settings will not be saved.
• To save and exit immediately out of APM to Normal Operation, Press and Hold the Tap button until Indicator
Lights stop blinking.
L
IL1
T
T