CHECKING PRODUCT TEMPERATURE
To accurately check the temperature of the product
stored in a refrigerated compartment, insert an accurate
thermometer into a plastic (non-breakable) bottle, partial-
ly filled with water. Tighten the bottle cap securely.
Place the bottle in the desired area for 24 hours. Refrain
from opening the unit during the testing period. After 24
hours, check the temperature of the water. Adjust the
control settings if necessary and re-test.
Your Lynx units are pre-set in order to achieve the rec-
ommended temperature range when installed in a 70°F
ambient temperature. Factors, which affect the internal
temperatures of the refrigerated cabinet, include:
Temperature setting
Room temperature where installed
Number of times the door is opened and closed
Length of times the door is opened and closed
Length of times the door is left open
Style of door installed
Door gasket sealing and condition
Amount of time the internal light is illuminated
Installation in direct sun light or near a heat source
LIGHT BULB REPLACEMENT
To replace a defective or burnt out light bulb, unscrew
the bulb counterclockwise and replace with an identical
15-Watt bulb or smaller. Contact Lynx for a replacement
bulb.
MAINTENANCE
CLEANING
To clean stainless steel exterior or interior surfaces, use a
soft, non-abrasive stainless steel cleaner to wipe down the
these surfaces.
To clean interior and exterior non-metallic surfaces and
removable parts, wash with a mild solution of soap and
lukewarm water with a little baking soda. Rinse and dry
thoroughly. Avoid getting water on lights, controllers, fan
motors, and unfinished wood wine rack faces.
CAUTION:
Do not use abrasive cleaners or cloths on any of the interi-
or or exterior surfaces or removable parts.
CONDENSER CLEANING
WARNING
For cleaning the condenser and other routine mainte-
nance, shut off electricity to the unit.
In all instances, you should clean the condenser area eve-
ry three months. The condenser is located behind the lou-
vered toe plate. To clean the condenser remove the toe
plate and use a soft bristle brush and vacuum to remove
dust and lint. Avoid damaging or crushing the condenser
fins or tubing. Upon completion, re-install the louvered toe
plate.
CAUTION
Failure to clean the condenser could result in temperature
loss or mechanical failure or damages. Clean this area
every three months.