EasyManuals Logo
Home>Lynx>Refrigerator>L24DWR

Lynx L24DWR User Manual

Lynx L24DWR
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
Make sure that the opening where the unit is to be in-
stalled is properly prepared. Refer to Figure 1 to en-
sure the space dimensions and electrical service are
correct for the models to be installed.
CAUTION:
If unit is being installed under a counter top it is recom-
mended that the counter top be supported by structure
other than the refrigerated cabinet to prevent damage
to the counter top.
IMPORTANT NOTE: Allow 24” clearance in front of
the unit for drawer pull-out.
IMPORTANT NOTE: Make sure the floor under the
unit is level with the surrounding finished floor. Protect
a finished floor with plywood, cardboard or some other
suitable material before moving the unit into place.
Failure to do this may result in damage to the floor.
PREPARING ELECTRICAL CONNECTIONS
A 115 volt, 60Hz, 15 amp circuit with GFI protection
and electrical supply are required. A separate circuit is
required for each Lynx unit installed.
Follow the National Electrical Code and local codes
and ordinances when installing the receptacle.
All Lynx units come equipped with a NEMA 5-15P 90°
plug with a minimum of 5-feet of cord extending be-
yond the rear of the cabinet. The electrical outlet must
be flush with or recessed into the back wall.
IMPORTANT NOTE: Never use an extension cord to
extend the power cord to the electrical receptacle.
DANGER:
ELECTROCUTION HAZARD!!
Electrical grounding required. This appliance is
equipped with a three prong (grounding) polarized plug
for your protection against possible shock hazards.
Never remove the round grounding prong from the
plug.
Never use a two-prong grounding adapter.
Never use extension cord to connect power to the
unit.
Where a two-prong wall receptacle is encountered or a
longer power cord is required, contact a qualified electri-
cian to have it replaced in accordance with applicable
electrical codes.
DANGER:
Failure to comply with the above electrical guidelines
may result in possible injury/death/fire or loss of property.
UNPACKING AND MOVING
CAUTION:
Do not cut cardboard sleeve covering the unit. Cutting
may result in damage to the exterior of the cabinet.
Uncrate the unit outside on a flat level surface. Re-
move the cardboard sleeve by removing the banding
holding the sleeve to the shipping base. Carefully lift
the cardboard sleeve up over the top of the unit.
Carefully lift unit off base and onto a hand truck or
dolly (this should be done with a minimum of two
people; larger units may require additional helpers).
Make sure unit is balanced on transporting device.
Secure unit to transporting device using soft, flexible
strapping. Protect unit surfaces with cloth material
where strapping contacts unit.
Before moving unit, secure door to unit with tape to
the door closed.
Carefully move unit to installation site and place in
front of opening.
WARNING:
A minimum of two people should lift the unit of the base
to prevent possible personal injury.
PREPARING THE SPACE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lynx L24DWR and is the answer not in the manual?

Lynx L24DWR Specifications

General IconGeneral
BrandLynx
ModelL24DWR
CategoryRefrigerator
LanguageEnglish

Related product manuals