User Guide ♦ 48
Request Stored Preset (Message ID 5)
When Black Box receives this request, it responds by sending the requested preset as a “Transmit Preset” message.
Status Description
1111 0000 System Exclusive (SysEx) ID
0000 0000 M-Audio ID byte 1 = 00h
0000 0001 M-Audio ID byte 2 = 01h
0000 0101 M-Audio ID byte 3 = 05h
0000 0001 Black Box family code LSB (always 01h)
0000 0000 Black Box family code MSB (always 00h)
0000 0010 Black Box family member ID LSB = 02h
0000 0000 Black Box family member ID MSB = 00h
0000 0101 Message ID for “Request stored preset”
0000 000b Bank select – 0 for factory preset, 1 for user preset
0nnn nnnn Requested preset number, 0 to 99
1111 0111 End of Exclusive (EOX)
Select Drumbeat (Message ID 8)
When Black Box receives this request, it responds by making the requested drumbeat number active.
Status Description
1111 0000 System Exclusive (SysEx) ID
0000 0000 M-Audio ID byte 1 = 00h
0000 0001 M-Audio ID byte 2 = 01h
0000 0101 M-Audio ID byte 3 = 05h
0000 0001 Black Box family code LSB (always 01h)
0000 0000 Black Box family code MSB (always 00h)
0000 0010 Black Box family member ID LSB = 02h
0000 0000 Black Box family member ID MSB = 00h
0000 1000 Message ID for ‘Select drumbeat”
0nnn nnnn Requested drumbeat number, 0 to 99
1111 0111 End of Exclusive (EOX)