K12-R sealing unit
English languageOperation and maintenance manual
Cutting blade cleaning
The gure shows the points of intervention and the description shows the proce-
dures to be adopted.
The intervention must be carried
out with the machine stopped in
safety conditions.
Att
en
ti
on
Warning
Wear the suitable personal protective
equipment (gloves) to avoid any cut-
ting hazard.
1. Lift guard A and keep it in position by
means of lever B.
2. Clean blade C from glue residues.
We recommend the using solvent , to
remove glue residue.
3. Spread a thin layer of lubricant on
blade C in order to avoid the accu-
mulation of glue residues.
4. Release lever B.
Guard A returns to its position.
5. Repeat the operation on the other
equal component.